首页> 外文期刊>Journal of vascular surgery >Intraoperative autotransfusion in aortic surgery: comparison of whole blood autotransfusion versus cell separation.
【24h】

Intraoperative autotransfusion in aortic surgery: comparison of whole blood autotransfusion versus cell separation.

机译:主动脉外科术中的术中自同种植:全血自同种灌注与细胞分离的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: Differences concerning alteration of hemostatic, hemolysis, and hematologic parameters after transfusion of blood from a cell-separation (CS) device or whole blood autotransfusion (WBA) were prospectively evaluated during major aortic surgery. METHOD: Thirty-two patients were randomly selected to receive autologous retransfusion by using either WBA or a CS device. Coagulation and hematologic parameters and levels of hemolytic degradation products (HDP) were assessed in the retransfused blood and in the patients' plasma preoperatively and until 24 hours after autologous retransfusion, respectively. RESULTS: Mean volume of retransfused blood was 1072 +/- 473 ml in the WBA group and 556 +/- 504 in the CS group. Level of HDP (bilirubin, free hemoglobin [free HB], and lactic dehydrogenase [LDH] and hemostatic disturbances (d-dimer value, fibrin degradation products) were significantly higher in the WBA device compared with the CS blood. Blood samples taken from the WBA group revealed significantly higher level of HDP (free HB, LDH) and of d-dimer values after autotransfusion compared with the CS group. CONCLUSION: Levels of HDP and the degree of hemostatic disturbances were significantly higher in retransfused whole blood compared with CS blood. Hemostatic disturbances and levels of HDP were significantly pronounced in the patients' plasma after WBA compared with CS. CS retransfused blood seems to be of superior quality compared with WBA and the degree of hemolysis and hemostatic disturbances is minor after CS retransfusion.
机译:目的:在主要主动脉术期间前瞻性地评估血液溶血,溶血和血液学参数改变血液溶解,血液溶解和血液学参数的差异。在主要主动脉外科期间进行了预期评估血液自血杂种(WBA)。方法:通过使用WBA或CS器件随机选择三十二次患者接受自体重传。在术前和患者的血浆中,分别在术前和患者的血浆中评估凝血和血液学参数和溶血性降解产物(HDP)的水平,并分别在自体重新抵抗后24小时。结果:在WBA组中的平均重回血液的体积为1072 +/- 473ml,CS组中的556 +/- 504。与CS血液相比,WBA器件中,HDP水平(胆红素,游离血红蛋白[游离HB]和乳酸脱氢酶[LDH]和止血紊乱(D-二聚体值,纤维蛋白降解产物)显着较高。血液样本取自与CS组相比,WBA组揭示了自体反应后的高温含量高(Free HB,LDH)和D-二聚体值。结论:与CS血液相比,HDP水平和止血干扰程度明显较高与CS相比,WBA后患者血浆中止血干扰和HDP的水平显着明显。与WBA相比,CS再抛弃血液似乎具有卓越的品质,并且在CS重回后的溶血和止血干扰程度较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号