...
首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Simultaneous determination of 15 BTEX hydroxyl biomarkers in urine by headspace solid-phase microextraction gas chromatography-mass spectrometry
【24h】

Simultaneous determination of 15 BTEX hydroxyl biomarkers in urine by headspace solid-phase microextraction gas chromatography-mass spectrometry

机译:通过顶空固相微萃取气相色谱 - 质谱法同时测定尿液中的15 btex羟基生物标志物

获取原文
获取原文并翻译 | 示例

摘要

Benzene (B), toluene (T), ethylbenzene (E), o-, m- and p-xylene (o-, m-, p-X) are ubiquitous and frequently exposed to human throughout the environment. Previously published test methods for phenolic biomarkers are not sensitive enough to be detected in most general population groups and require a lot of labor. A simple and convenient headspace solid-phase microextraction (HS-SPME) gas chromatography-mass spectrometry method was described for the simultaneous determination of 15 hydroxyl biomarkers of BTEX in urine. Hydroxyl biomarkers in urine were vaporized and adsorbed onto a selected fiber after enzyme hydrolysis with beta-glucuronidaseiarylsulfatase. The optimal HS-SPME conditions were achieved with an 85-mu m-carboxen-polydimethylsiloxane fiber, an extraction temperature of 70 degrees C, a heating time of 30 min, and a pH of 4.0. The desorption was performed for 1 min at 250 degrees C. Under the established conditions, the lowest limits of detection were from 0.02 to 0.15 mu g/L in 5.0 mL of urine, and the intra- and inter-day relative standard deviations were less than 12.7% at 0.5, 2.0, 50, and 200 mu g/L. The calibration curve demonstrated good linearity with greater than r(2) = 0.99 in synthetic urine. This method is convenient, simple, environmentally friendly, and amenable to automation. (C) 2019 Elsevier B.V. All rights reserved.
机译:苯(B),甲苯(T),乙苯(E),O-,M-和对二甲苯(O-,M-,P-X)是普遍存在的并且经常暴露于整个环境中的人。以前公布的酚醛生物标志物的试验方法不足以在大多数一般人群中检测到足够敏感,并且需要大量的劳动力。描述了简单方便的顶空固相微萃取(HS-SPME)气相色谱 - 质谱法,用于同时测定尿液中BTEX的15个羟基生物标志物。尿液中羟基生物标志物蒸发并吸附在酶水解后用β-葡糖醛酸盐酶酰胺酶硫酸盐酶进行蒸发到选定的纤维上。用85μm-carboxen - 聚二甲基硅氧烷纤维,70℃的提取温度,30分钟的加热时间和4.0的pH为4.0的最佳HS-SPME条件。在250摄氏度下进行解吸1分钟。在既定条件下,最低检测限为0.02至0.15μg/ l在5.0ml尿液中,并且内部和日间相对标准偏差较少比0.5,2.0,50和200μg/升为12.7%。校准曲线在合成尿液中表现出良好的线性度,大于R(2)= 0.99。这种方法方便,简单,环保,自动化。 (c)2019 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号