Accuracy Validation of Neuronavigation Comparing Headholder-Based System with Head-Mounted Array—A Cadaveric Study

机译:头部阵列尸体阵列尸体系统的准确性验证 - 尸体研究 - 尸体研究

获取原文
获取原文并翻译 | 示例
           

摘要

BackgroundNeuronavigation is widely used for intracranial neurosurgical procedures and is commonly based on the standard reference array being fixed to the headholder. Some cases require the reference array to be attached directly to the head. The aim of this cadaveric study was to compare operational accuracy of a head-mounted reference array with the standard headholder-based system. MethodsNavigation accuracy was evaluated with 10 cadaveric specimens. Each specimen was prepared with 8 titanium microscrews that served as reference points on the external skull, and computed tomography was performed. Registration of all specimens was done using surface matching with infrared laser on three-dimensional reconstructed high-resolution computed tomography. In all 10 specimens, the head-mounted reference array and headholder-based system were compared by 10 repetitive measurements. The deviation was evaluated for each screw and compared using nonparametric Mann-WhitneyUtest between groups and screws. A Bland-Altman plot was generated for comparison. ResultsA total of 1600 measurements were conducted. Mean deviation was 1.97 mm (95% confidence interval, 1.90–2.03 mm) with the head-mounted reference array and 2.10 mm (95% confidence interval, 2.04–2.18 mm) with the headholder based system. There was no significant difference between methods in 9 of 10 specimens. In 1 specimen, the head-mounted array was superior. The deviation in either method showed a significant correlation, indicating high pertinence for registration (P< 0.001). ConclusionsNavigation with the head-mounted reference array demonstrated comparable accuracy to the headholder-based system and can be used without reduced accuracy. Careful registration is mandatory.
机译:BackgroundNeuronavigation被广泛用于颅内神经外科手术,并且通常基于标准参考阵列固定到headholder。某些情况下,所需要的参考阵列被直接附接到头部。此尸体研究的目的是比较用标准的基于headholder系统头戴式参考阵列的操作精度。 MethodsNavigation精度用10个尸体标本进行评估。每个试样用8个钛microscrews投放作为参考点上的外部头骨,并进行计算机断层摄影制备。所有标本的注册被三维重建高分辨率计算机断层摄影使用表面匹配用红外激光来完成。在所有10个样品,基于headholder头戴式参考阵列和系统,通过10个重复测量进行比较。的偏差进行评价为每个螺丝和使用组和螺钉之间非参数Mann-WhitneyUtest比较。比较生成一个奥特曼的情节。结果共1600个测量进行。平均偏差为1.97毫米(95%置信区间,1.90-2.03毫米)和拥有headholder基于系统中的头戴式参考阵列2.10毫米(95%置信区间,2.04-2.18毫米)。有10个9的样本方法没有显著差异。在1个样品中,头戴式阵列优异。在任一方法中的偏差呈显著相关性,指示用于登记高相符合(P <0.001)。 ConclusionsNavigation与头戴式参考阵列表明可比的精度到基于headholder系统并且可以在不降低精度来使用。小心登记是强制性的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号