首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Gas chromatographic-sulfur chemiluminescent detector procedures for the simultaneous determination of free forms of volatile sulfur compounds including sulfur dioxide and for the determination of their metal-complexed forms
【24h】

Gas chromatographic-sulfur chemiluminescent detector procedures for the simultaneous determination of free forms of volatile sulfur compounds including sulfur dioxide and for the determination of their metal-complexed forms

机译:用于同时测定包含硫二氧化硫的自由形式的挥发性硫化合物的气相色谱 - 硫化学发光探测器探测器程序和用于测定其金属络合物形式

获取原文
获取原文并翻译 | 示例
           

摘要

Three different procedures for the quantitative assessment of free and metal complexed volatile sulfur compounds (VSCs) and for the determination of truly free SO2 have been developed, taking advantage of a GC-sulfur chemiluminescent detector system (GC-SCD) with cryotrapping. The inertness of the inlet systems, together with the column used (SPB-1 sulfur) makes it possible to obtain a non-saturated perfectly Gaussian peak for SO2, well resolved from H2S. In the main procedure, the injection of 1 mL of the headspace of a sample prepared in complete anoxia and equilibrated at 30 degrees C makes it possible to get highly sensitive signals for all VSCs and free SO2. Detection limits are 3, 35 and 60 ng/L for H2S, MeSH and EtSH, 13 mu g/L for truly free SO2 (at pH = 3.4, or 0.46 mu g/L for molecular SO2), and better than 1 mu g/L for other relevant sulfur volatiles. Method precision is also satisfactory and linearity covers the whole range of occurrence of these compounds. A second procedure, not making use of the cryotrapping unit, gives also satisfactory results, although with higher detection limits (0.03, 0.25 and 0.37 mu g/L for free H2S, MeSH and EtSH, respectively). For the analysis of free plus metal-complexed forms, it has been demonstrated that the headspace injection of the vapors on a 1:10 brine dilution of the sample heated at 70 degrees C for 25 min, gives good estimates of the free + metal-complexed forms of H2S and wine mercaptans. (C) 2019 Elsevier B.V. All rights reserved.
机译:已经开发了三种不同程序,用于定量评估自由和金属络合物挥发性硫化合物(VSC)和用于测定真正的游离SO2,利用GC-硫化学发光探测器系统(GC-SCD),具有冷冻运动。入口系统的惰性与所用柱(SPB-1硫)一起使得可以获得SO2的非饱和完全高斯峰,从H2S溶解。在主要方法中,在30℃下在完全缺氧中制备的样品的1ml顶部空间使得可以获得所有VSC和游离SO2的高敏感信号。对于H 2 S,网状物和ETSH,13μg/ L的检测限为35和60ng / L,用于真正的游离SO 2(在pH = 3.4,或分子SO 2的0.46μg/ L),优于1μg / L对于其他相关的硫挥发物。方法精度也是令人满意的,线性度覆盖这些化合物的整个发生范围。第二个程序,不利用呼吸桥单元,也给出了令人满意的结果,尽管具有较高的检测限(0.03,0.25和0.37μg/ l,用于自由H 2 S,网格和Etsh)。对于自由加金属络合物形式的分析,已经证明了在70℃下加热的样品的1:10盐水稀释的顶部空间注射蒸汽25分钟,给出了自由+金属的良好估计复合形式的H2S和酒硫醇。 (c)2019 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号