首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Handling of highly coeluted chromatographic peaks by multivariate curve resolution for a complex bioanalytical problem: Quantitation of selected corticosteroids and mycophenolic acid in human plasma
【24h】

Handling of highly coeluted chromatographic peaks by multivariate curve resolution for a complex bioanalytical problem: Quantitation of selected corticosteroids and mycophenolic acid in human plasma

机译:通过多变量曲线分辨率处理复杂生物分析问题的高度共面色谱峰:在人血浆中定量选择皮质类固醇和霉蛋白的定量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The present study describes the analytical performance of a fast-elution protocol and smart methodology based on multivariate curve resolution-alternating least square (MCR-ALS) modeling of high performance liquid chromatography with photodiode-array detection (HPLC-DAD) data for simultaneous determination of prednisolone (Predl), methylprednisolone (Mpredl) and mycophenolic acid (MPA) in plasma samples. The LC method optimized at two isocratic reverse phase over a symmetric C18 column, a 60:40 (v/v) mixture of acetonitrile and water (0.02 M KH2PO4 (pH = 3.7) buffer solution) and a 10:70:20 (v/v/v) mixture of acetonitrile, methanol and water. The most challenges in the present study were the severe coelution of analytes of interest with each other and the matrix interferences, and high spectral similarity of selected corticosteroids, depending on the mobile phase method. To circumvent these drawbacks, the whole chromatographic runs were divided into two sections. Then, the matrix augmentation in spectra and retention time direction were implemented for the first and second regions, respectively. Highly acceptable resolution and quantification results were obtained. The average recoveries were 97.3% and 102.1% for Predl, 96% and 98.6% for Mpredl and 97.7% and 100.8% for MPA, using two mobile phase conditions, respectively. Accurate and precise results, elimination of expensive and time consuming sample pretreatment steps and a very short chromatographic run time, are among the advantages of the presented method.
机译:本研究描述了基于多变量曲线分辨率 - 交替的高性能液相色谱与光电二极管阵列检测(HPLC-DAD)数据进行同时测定的快速曲线分辨率和智能方法的分析性能。同时测定血浆样品中雷尼斯龙(Pred1),甲基丙酮(MPREDL)和霉酚酸(MPA)。在对称C18柱的两个等离子反相中优化的LC方法,乙腈和水的60:40(v / v)混合物(0.02m KH 2 PO 4(pH = 3.7)缓冲液)和10:70:20(V. / v / v)乙腈,甲醇和水的混合物。本研究中最多的挑战是彼此彼此的严重额,以及基质干扰,以及所选择的皮质类固醇的高光谱相似性,这取决于流动相法。为了规避这些缺点,整个色谱延时被分成两部分。然后,分别为第一和第二区域实现光谱和保留时间方向中的矩阵增强。获得了高度可接受的分辨率和定量结果。使用两个流动相条件,PERED1的平均回收率为97.3%,96%和98.6%,97.7%和100.8%,使用两个流动相条件。准确且精确的结果,消除昂贵且耗时的样品预处理步骤和非常短的色谱运行时间,是所提出的方法的优点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号