Preparation of a disposable and low-cost electrochemical sensor for propham detection based on over-oxidized poly(thiophene) modified pencil graphite electrode

机译:基于过氧化聚(噻吩)改性铅笔石墨电极的预防预防铅粉检测的一次性和低成本电化学传感器的制备

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this study, an electrochemical sensor was developed for the determination of propham (PRO) in potato, human urine and river water samples based on the over-oxidized poly(thiophene) modified pencil graphite [PG/p(Thp)-Ox] electrode. Adsorptive stripping differential pulse voltammetry was used as a voltammetric method. The PG/p(Thp)-Ox electrode increased the oxidation peak current of PRO 30 times according to bare PG. Electrochemical polymerization and over-oxidation conditions were deeply optimized to increase the sensitivity of PG/p(Thp)-Ox. Characterization of PG/p(Thp)-Ox was performed via scanning electron microscopy and cyclic voltammetry analysis. Oxidation peak current value of PRO linearly increased with the concentration of PRO in the ranges of 0.005-1.0 mu M and 2.0-15.0 mu M. A very low limit of detection value (1.0 nM) was obtained. Intra-day and inter-day reproducibility of the PG/p(Thp)-Ox were determined as 2.96% (N: 10) and 4.77% (10 days), respectively. Satisfactory recovery values (98.07-104.4%) were observed with PG/p(Thp)-Ox electrode during the analysis of PRO in PRO-spiked potato, urine and river water samples. The results show that the PG/p(Thp)-Ox could be used safely in the determination of PRO.
机译:在该研究中,基于过氧化的聚(噻吩)改性的铅笔石墨[PG / P(THP)-OX]电极,开发了一种电化学传感器用于测定马铃薯,人尿和河水水样中的预防(Pro) 。吸附剥离差分脉冲伏安法用作伏安法。 PG / P(THP)-OX电极根据裸PG增加PRO的氧化峰值电流。电化学聚合和过氧化条件深入优化,以增加PG / P(THP)-OX的敏感性。通过扫描电子显微镜和循环伏安法分析进行PG / P(THP)-OX的表征。 Pro的氧化峰值电流值随着0.005-1.0μmm和2.0-15.0μm的范围内的浓度线性增加。获得了检测值(1.0nm)的非常低限度。 PG / P(THP)-OX的日期和日间再现性分别测定为2.96%(N:10)和4.77%(10天)。在Pro-Spiked马铃薯,尿液和河水样品中,用PG / P(THP)-OX电极观察令人满意的恢复值(98.07-104.4%)。结果表明,PG / P(THP)-ox可以安全地使用在Pro的测定中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号