Abstract Using chiral amino amide ionic liquids as the ligands, a new chiral ligand exchange capillary electrophoresis method with Cu(II) as the central ion was constructed for enantioseparation of labeled D,L-amino acids. The effects of key parameters, including pH value of the running buffer, the ratio of Cu(II) to chiral amino amide ionic liquids, the concentration of complexes based on Cu(II)-chiral amino amide ionic liquids were investigated. It has been observed that eight pairs of labeled D,L-amino acids could be baseline-separated with a running buffer of 15.0mM ammonium acetate, 10.0mM Cu(II) and 20.0mML-phenylalaninamide based ionic liquid at pH 5.0. The quantitation of D,L-amino acids was conducted and good linearity (r2 ≥ 0.964) was obtained. Furthermore, an assay for determining the enantiomeric purity of D,L-amino acids was developed and the possible enantiorecognition mechanism was discussed briefly. The results indicated that the chiral amino amide ionic liquids could play the role of ligands in chiral ligand exchange capillary electrophoresis system and exhibit great potential in chiral analysis. Graphical abstract Display Omitted Highlights ? Chiral amino amide ionic liquids (CAAILs) were successfully synthesized. ? New CLE-CE system was constructed with CAAILs ligands for Dns-D,L-AAs separation. ? Well enantioseparation efficiency of the developed CLE-CE was achieved. ? The proposed CLE-CE method was applied for determination of enantiomeric purity. ]]>
机译:<![cdata [ 抽象 使用手性氨基酰胺离子液作为配体,为中心离子的Cu(II)的新的手性配体交换毛细管电泳方法标记的D,L-氨基酸的映对分析。研究了关键参数,包括运行缓冲液的pH值,Cu(II)与手性氨基酰胺离子液体的效果,研究了基于Cu(II)的复合物的浓度 - 将氨基酰胺离子液体进行研究。已经观察到,8对标记的D,L-氨基酸可以是基线 - 用15.0 氯乙酸铵的运行缓冲液分离,10.0 Mm Cu(II)和20.0 mm L-苯丙胺酰胺基离子液体在pH 5.0处。进行D,L-氨基酸的定量,得到良好的线性度(R 2 ≥0.964)。此外,开发了用于确定D,L-氨基酸的对映体纯度的测定,并且简要讨论了可能的肾炎机制。结果表明,手性氨基酰胺离子液体可以发挥配体在手性配体交换毛细管电泳系统中的作用,表现出对手性分析的巨大潜力。 图形抽象 显示省略 突出显示 成功合成了手性氨基酰胺离子液体(CAIALS)。 新的CLE-CE系统由CAIALS配体为DNS-D,L-AAS构建构建分离。 实现了发达的CLE-CE的阐述效率。 ?< / ce:标签> 拟议的c​​le-ce方法用于测定对映体纯度的测定。 ]]>

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号