首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >An organic-inorganic hybrid silica aerogel prepared by co-precursor method for solid-phase microextraction coating
【24h】

An organic-inorganic hybrid silica aerogel prepared by co-precursor method for solid-phase microextraction coating

机译:通过共 - 前体方法制备的有机无机杂化二氧化硅气凝胶,用于固相微萃取涂层

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In order to improve the extraction performance of silica aerogel, an organic-inorganic hybrid silica aerogel was developed as the coating of solid-phase microextraction (SPME). It was prepared via the co-precursor reaction between tris(triethoxysilylpropyl)amine and tetraethyl orthosilicate. Coupled with gas chromatography, the hybrid silica aerogel-coated SPME fiber was evaluated using polycyclic aromatic hydrocarbons (PAHs). Compared to silica aerogel, the hybrid silica aerogel displayed better extraction performance, peak areas of PAH analytes were increased by about 2 times. The affecting parameters including extraction time, extraction temperature, ionic strength, stirring rate and desorption time were optimized, and an analytical method was established with wide linear ranges (0.005-20 mu g L-1, 0.010-20 mu g L-1, 0.100-20 mu g L-1), good correlation coefficients (0.9967-0.9994), low limits of detection (0.001-0.030 mu g L-1) and limits of quantitation (0.005-0.100 mu g L-1). Satisfactory extraction repeatability (RSD = 6.1%, n = 3) and preparation repeatability (RSD = 9.8%, n = 3) were also obtained. Compared to the reported coatings and the commercial coating, the organic-inorganic hybrid silica aerogel has higher or comparable sensitivity, better repeatability, and shorter extraction time and longer service life. The established method was used for the detection of lake water and rain water, and some targets were quantified successfully.
机译:为了提高二氧化硅气凝胶的提取性能,开发有机 - 无机杂化二氧化硅气体作为固相微萃取(SPME)的涂层。它通过Tris(三乙氧基甲甲甲甲甲甲丙基)胺与苯甲酸四乙酯之间的共前体反应制备。使用多环芳烃(PAH)评价杂化二氧化硅气凝胶涂覆的SPME纤维。与二氧化硅气凝胶相比,杂交石英气凝胶显示出更好的提取性能,PAH分析峰的峰面积增加约2次。优化了提取时间,提取温度,离子强度,搅拌速率和解吸时间的影响参数,并用宽线性范围建立分析方法(0.005-20μg1-1,0.010-20μgl-1, 0.100-20 mu g l-1),相关系数良好(0.9967-0.994),检测极限(0.001-0.030 mu g l-1)和定量限制(0.005-0.100μmg l-1)。还获得了令人满意的提取重复性(RSD <= 6.1%,N = 3)和制备重复性(RSD <= 9.8%,N = 3)。与报告的涂层和商业涂层相比,有机 - 无机杂交二氧化硅气凝胶具有更高或相当的灵敏度,更好的重复性和更短的提取时间和更长的使用寿命。已建立的方法用于检测湖水和雨水,并成功地量化了一些靶标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号