首页> 外文期刊>Physics in medicine and biology. >External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction
【24h】

External force back-projective composition and globally deformable optimization for 3-D coronary artery reconstruction

机译:外力背部投影组合物和全球可变形优化3-D冠状动脉重建

获取原文
获取原文并翻译 | 示例
           

摘要

The clinical value of the 3D reconstruction of a coronary artery is important for the diagnosis and intervention of cardiovascular diseases. This work proposes a method based on a deformable model for reconstructing coronary arteries from two monoplane angiographic images acquired from different angles. First, an external force back-projective composition model is developed to determine the external force, for which the force distributions in different views are back-projected to the 3D space and composited in the same coordinate system based on the perspective projection principle of x-ray imaging. The elasticity and bending forces are composited as an internal force to maintain the smoothness of the deformable curve. Second, the deformable curve evolves rapidly toward the true vascular centerlines in 3D space and angiographic images under the combination of internal and external forces. Third, densely matched correspondence among vessel centerlines is constructed using a curve alignment method. The bundle adjustment method is then utilized for the global optimization of the projection parameters and the 3D structures. The proposed method is validated on phantom data and routine angiographic images with consideration for space and re-projection image errors. Experimental results demonstrate the effectiveness and robustness of the proposed method for the reconstruction of coronary arteries from two monoplane angiographic images. The proposed method can achieve a mean space error of 0.564 mm and a mean re-projection error of 0.349 mm.
机译:冠状动脉三维重建的临床价值对于心血管疾病的诊断和干预是重要的。该工作提出了一种基于可变形模型的方法,用于从不同角度获取的两种单体血管造影图像重建冠状动脉。首先,开发了外力回落组合物模型以确定外力,其中不同视图中的力分布在基于X-的透视投影原理基于透视投影原理将不同视图中的力分布在相同的坐标系中进行回程。射线成像。弹性和弯曲力作为内部力,以保持可变形曲线的平滑度。其次,可变形曲线在内部和外力的组合下快速发展到3D空间的真正血管中心线和血管造影图像。第三,使用曲线对准方法构建血管中心线之间的密集匹配对应关系。然后利用束调节方法用于投影参数和3D结构的全局优化。考虑到空间和重新投影图像误差,在幻像数据和常规血管造影图像上验证了所提出的方法。实验结果表明,来自两种单岩血管造影图像的冠状动脉重建方法的有效性和稳健性。所提出的方法可以实现0.564mm的平均空间误差和0.349mm的平均重新投影误差。

著录项

  • 来源
    《Physics in medicine and biology.》 |2014年第4期|共29页
  • 作者单位

    Key Laboratory of Photoelectronic Imaging Technology and System Beijing Institute of Technology;

    Key Laboratory of Photoelectronic Imaging Technology and System Beijing Institute of Technology;

    Laboratory of Image Science and Technology Southeast University Nanjing 210096 China;

    Key Laboratory of Photoelectronic Imaging Technology and System Beijing Institute of Technology;

    Key Laboratory of Photoelectronic Imaging Technology and System Beijing Institute of Technology;

    Key Laboratory of Photoelectronic Imaging Technology and System Beijing Institute of Technology;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 R35;
  • 关键词

    angiography; coronary artery; deformable model; reconstruction;

    机译:血管造影;冠状动脉;可变形模型;重建;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号