On-line in situ determination of deuterium content in water via FTIR spectroscopy

机译:通过FTIR光谱法在原位测定水中氘含量的直线测定水中氘含量

获取原文
获取原文并翻译 | 示例
           

摘要

Hydrogen stable isotope ratios are critical indicators in environmental geochemical studies for characterizing runoff, determination of groundwater groups and water uptake by plants etc. (generally used in combination with O-18 analysis). While the common technique for this hydrogen isotope measurement is Mass Spectrometry, FTIR (Fourier transform infra-red) spectroscopy may be an alternative method, with the advantage of direct and simple operating measurements. The FTIR spectrometer has the advantage of performing in situ measurements, which can delineate continuous geochemical processes. In situ measurements decrease errors that may be a consequence of sample delivery to the laboratory and off-site analysis procedures. In this study, we have developed a new simple procedure for in situ hydrogen stable isotope ratio measurements. We discovered that the HDO (hydrogen, deuterium, and oxygen) absorbance peak at 2504 cm(-1) is the most suitable for water sample direct analysis, with the FTIR device, using a circular sample cell for liquid samples. A case study analyzing water samples from a karstic cave (Sif cave, Israel) verified the following: (a) on-line determination of water D/H ratio can be carried out with the portable FTIR spectrometer (and thus can be used for field measurements such as in the Sif cave) and (b) the D concentration sensitivity achieved was at a 0.01 parts per thousand level, with a standard deviation of 0.006 parts per thousand.
机译:氢稳定的同位素比是用于表征径流的环境地球化学研究中的关键指标,植物的地下水基团的测定等(通常与O-18分析组合使用)。虽然该氢同位素测量的常用技术是质谱法,但FTIR(傅里叶变换红外线)光谱可以是一种替代方法,具有直接和简单的操作测量的优点。 FTIR光谱仪具有以原位测量执行的优点,可以描绘连续地球化学过程。在原位测量中,降低可能是对实验室和非现场分析程序的样品输送的结果的误差。在这项研究中,我们开发了一种原位氢稳定同位素比率的新简单方法。我们发现,2504cm(-1)的HDO(氢气,氘和氧)吸收峰是用FTIR器件使用液体样品的圆形样品电池的水样直接分析最适合的水样直接分析。案例研究分析来自岩溶洞穴(SIF洞穴,以色列)的水样验证以下内容:(a)水D / H比的线测定可以用便携式FTIR光谱仪进行(因此可用于场诸如SIF洞中的测量值和(B)D浓度敏感性达到0.01份每千份,标准偏差为0.006份‰。

著录项

  • 来源
    《RSC Advances》 |2018年第50期|共8页
  • 作者单位

    Ariel Univ Dept Chem Engn Ariel Israel;

    Ariel Univ Dept Chem Engn Ariel Israel;

    Ariel Univ Dept Chem Sci Ariel Israel;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号