Self-Calibration of Angular Position Sensors by Signal Flow Networks

机译:信号流量网络的角度位置传感器的自校准

获取原文
获取原文并翻译 | 示例
           

摘要

Angle position sensors (APSs) usually require initial calibration to improve their accuracy. This article introduces a novel offline self-calibration scheme in which a signal flow network is employed to reduce the amplitude errors, direct-current (DC) offsets, and phase shift without requiring extra calibration instruments. In this approach, a signal flow network is firstly constructed to overcome the parametric coupling caused by the linearization model and to ensure the independence of the parameters. The model parameters are stored in the nodes of the network, and the intermediate variables are input into the optimization pipeline to overcome the local optimization problem. A deep learning algorithm is also used to improve the accuracy and speed of convergence to a global optimal solution. The results of simulations show that the proposed method can achieve a high identification accuracy with a relative parameter identification error less than 0.001 parts per thousand. The practical effects were also verified by implementing the developed technique in a capacitive APS, and the experimental results demonstrate that the sensor error after signal calibration could be reduced to only 6.98%.
机译:角度位置传感器(APS)通常需要初始校准以提高其准确性。本文介绍了一种新的离线自校准方案,其中使用信号流量网络来减少幅度误差,直流(DC)偏移和相移,而无需额外的校准仪器。在这种方法中,首先构造信号流网络以克服由线性化模型引起的参数耦合,并确保参数的独立性。模型参数存储在网络的节点中,中间变量被输入到优化流水线中以克服本地优化问题。深度学习算法还用于提高到全局最优解决方案的收敛准确性和速度。仿真结果表明,该方法可以通过相对参数识别误差达到小于0.001零件的高识别精度。还通过在电容APS中实施开发技术来验证实际效果,实验结果表明信号校准后的传感器误差仅为6.98%。

著录项

  • 来源
    《Nature reviews Cancer》 |2018年第8期|共18页
  • 作者单位

    Tsinghua Univ Dept Precis Instrument Engn Res Ctr Nav Technol Beijing 100084 Peoples R China;

    Tsinghua Univ Dept Precis Instrument Engn Res Ctr Nav Technol Beijing 100084 Peoples R China;

    Tsinghua Univ Dept Precis Instrument Engn Res Ctr Nav Technol Beijing 100084 Peoples R China;

    Tsinghua Univ Dept Precis Instrument Engn Res Ctr Nav Technol Beijing 100084 Peoples R China;

    Tsinghua Univ Dept Elect Engn Beijing 100084 Peoples R China;

    Tsinghua Univ Dept Precis Instrument Engn Res Ctr Nav Technol Beijing 100084 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 肿瘤学;
  • 关键词

    self-calibration; signal flow network; signal processing; angular position sensor;

    机译:自校准;信号流量网络;信号处理;角度位置传感器;