首页> 外文期刊>Medical Physics >On the data acquisition, image reconstruction, cone beam artifacts, and their suppression in axial MDCT MDCT and CBCT CBCT – A review
【24h】

On the data acquisition, image reconstruction, cone beam artifacts, and their suppression in axial MDCT MDCT and CBCT CBCT – A review

机译:关于数据采集,图像重建,锥形束伪像及其在轴向MDCT MDCT中的抑制和CBCT CBCT - 评论

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose In the clinic, computed tomography ( CT ) has evolved into an essential modality for diagnostic imaging by multidetector row CT ( MDCT ) and image guided intervention by cone beam CT ( CBCT ). Recognizing the increasing importance of axial MDCT / CBCT in clinical and preclinical applications, and the existence of CB artifacts in MDCT / CBCT images, we provide a review of CB artifacts’ root causes, rendering mechanisms and morphology, and possible solutions for elimination and/or reduction of the artifacts. Methods By examining the null space in Radon and Fourier domain, the root cause of CB artifacts (i.e., data insufficiency) in axial MDCT / CBCT is analytically investigated, followed by a review of the data sufficiency conditions and the “circle +” source trajectories. The rendering mechanisms and morphology of CB artifacts in axial MDCT / CBCT and their special cases (e.g., half/short scan and full scan with latitudinally displaced detector) are then analyzed, followed by a survey of the potential solutions to suppress the artifacts. The phenomenon of imaged zone indention and its variation over FBP , BPF / DBPF , two‐pass and iterative CB reconstruction algorithms and/or schemes are discussed in detail. Results An interdomain examination of the null space provides an insightful understanding of the root cause of CB artifacts in axial MDCT / CBCT . The decomposition of CB artifacts rendering mechanisms facilitates understanding of the artifacts’ behavior under different conditions and the potential solutions to suppress them. An inspection of the imaged zone intention phenomenon provides guidance on the design and implementation of CB image reconstruction algorithms and schemes for CB artifacts suppression in axial MDCT / CBCT . Conclusions With increasing importance of axial MDCT / CBCT in clinical and preclinical applications, this review article can update the community with in‐depth information and clarification on the latest progress in dealing with CB artifacts and thus increase clinical/preclinical confidence.
机译:目的在诊所中,计算机断层扫描(CT)已经演变为通过多传输号码CT(MDCT)的诊断成像和通过锥梁CT(CBCT)的图像引导干预的基本模态。认识到轴向MDCT / CBCT在临床和临床前应用中的重要性,以及MDCT / CBCT图像中的CB文物的存在,我们提供了对CB伪影的根本原因,渲染机制和形态的审查,以及消除和/的可能解决方案或减少伪影。通过检查氡和傅里叶域中的空空间,分析轴MDCT / CBCT中的CB伪影(即数据不足)的根本原因,进行了分析研究,然后审查数据充足条件和“圆+”源轨迹。然后分析了轴向MDCT / CBCT中CB伪影的渲染机制和形态及其特殊情况(例如,半/短扫描和全扫描),然后进行抑制伪影的潜在解决方案的调查。详细讨论了成像区凝结的现象及其对FBP,BPF / DBPF,双通和迭代CB重建算法和/或方案的变化。结果互空空间的互联互联检查对轴向MDCT / CBCT中CB伪影的根本原因提供了深入的了解。 CB伪影渲染机制的分解有助于了解在不同条件下的伪影行为和抑制它们的潜在解决方案。对成像区意图现象的检查提供了关于CB图像重建算法的设计和实现的指导,并且在轴向MDCT / CBCT中CB伪影抑制的方案。结论伴随轴向MDCT / CBCT在临床和临床前应用中的重要性,这篇综述文章可以通过深入的信息更新社区,并澄清处理CB伪影的最新进展,从而提高临床/临床前的信心。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号