首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Development of a flat membrane based device for electromembrane extraction: A new approach for exhaustive extraction of basic drugs from human plasma
【24h】

Development of a flat membrane based device for electromembrane extraction: A new approach for exhaustive extraction of basic drugs from human plasma

机译:基于平膜的电膜提取装置的开发:从人血浆中彻底提取基础药物的新方法

获取原文
获取原文并翻译 | 示例
           

摘要

In this work, a single-well electromembrane extraction (EME) device was developed based on a thin (100μm) and flat porous membrane of polypropylene supporting a liquid membrane. The new EME device was operated with a relatively large acceptor solution volume to promote a high recovery. Using this EME device, exhaustive extraction of the basic drugs quetiapine, citalopram, amitriptyline, methadone and sertraline was investigated from both acidified water samples and human plasma. The volume of acceptor solution, extraction time, and extraction voltage were found to be important factors for obtaining exhaustive extraction. 2-Nitrophenyl octyl ether was selected as the optimal organic solvent for the supported liquid membrane. From spiked acidified water samples (600 μl), EME was carried out with 600 μl of 20 mM HCOOH as acceptor solution for 15 min and with an extraction voltage of 250 V. Under these conditions, extraction recoveries were in the range 89-112%. From human plasma samples (600 μl), EME was carried out with 600 μl of 20 mM HCOOH as acceptor solution for 30 min and with an extraction voltage of 300 V. Under these conditions, extraction recoveries were in the range of 83-105%. When combined with LC-MS, the new EME device provided linearity in the range 10-1000ng/ml for all analytes (R2 > 0.990). The repeatability at low (10ng/ml), medium (100 ng/ml), and high (1000 ng/ml) concentration level for all five analytes were less than 10% (RSD). The limits of quantification (S/N= 10) were found to be in the range 0.7-6.4 ng/ml.
机译:在这项工作中,基于支撑液体膜的聚丙烯薄(100μm)和平坦的多孔膜,开发了单孔电膜萃取(EME)装置。新的EME设备以相对较大的受体溶液量运行,以促进高回收率。使用该EME设备,从酸化的水样和人体血浆中彻底提取了基本药物喹硫平,西酞普兰,阿米替林,美沙酮和舍曲林。发现受体溶液的体积,萃取时间和萃取电压是获得详尽萃取的重要因素。选择2-硝基苯基辛基醚作为负载型液膜的最佳有机溶剂。从加标的酸化水样品(600μl)中,用600μl的20 mM HCOOH作为受体溶液进行15分钟,萃取电压为250 V,进行EME。在这些条件下,萃取回收率在89-112%的范围内。从人血浆样品(600μl)中,用600μl的20 mM HCOOH作为受体溶液进行30分钟,萃取电压为300 V进行EME。在这些条件下,萃取回收率在83-105%的范围内。当与LC-MS结合使用时,新的EME设备可为所有分析物提供10-1000ng / ml范围内的线性(R2> 0.990)。所有五种分析物在低(10ng / ml),中(100 ng / ml)和高(1000 ng / ml)浓度水平下的重复性均小于10%(RSD)。发现定量极限(S / N = 10)在0.7-6.4ng / ml的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号