首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry
【24h】

Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry

机译:分析河水中的18种全氟化合物:高效液相色谱-串联质谱法,超高效液相色谱-串联质谱法和毛细管液相色谱-质谱法的比较

获取原文
获取原文并翻译 | 示例
       

摘要

In this work, the performance of ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and capillary liquid chromatography-mass spectrometry (CLC-MS) has been studied for the analysis of eighteen perfluorinated compounds in water samples. UHPLC-MS/MS and CLC-MS analysis were carried out using a Zorbax C-18 column (50mm×2.1mm, 1.8μm) and a Zorbax SB-C18 column (150mm×0.5mm, 3.5μm), respectively, in gradient elution mode with a mobile phase of ammonium formate and methanol. Both techniques were compared with conventional LC-MS/MS in terms of speed, sensitivity, selectivity and resolution. Water samples were extracted by solid phase extraction (SPE). Mean absolute recoveries at two concentration levels, 6 and 60ngL ~(-1), calculated from the eighteen compounds were: 77±12(s) and 82±12(s), respectively. Relative standard deviation (RSD) was lower than 16% for each perfluorinated compound. The results obtained showed that UHPLC-MS/MS and CLC-MS allow the determination of perfluorinated compounds in water samples with satisfactory sensitivity and resolution and reduced analysis time. Therefore, both techniques were employed for the analysis of water samples to determine the target analytes at low concentration levels and with lower analysis times than using HPLC-MS/MS. Similar statistical values were obtained from both techniques at 95% confidence level. Several compounds have been detected, but perfluorooctanoic acid (PFOA) (171ngL ~(-1) and 148ngL ~(-1) by UHPLC-MS/MS and CLC-MS, respectively) showed the highest concentration.
机译:在这项工作中,研究了超高效液相色谱-串联质谱(UHPLC-MS / MS)和毛细管液相色谱-质谱(CLC-MS)的性能,用于分析水中的18种全氟化合物。 。使用Zorbax C-18色谱柱(50mm×2.1mm,1.8μm)和Zorbax SB-C18色谱柱(150mm×0.5mm,3.5μm)分别进行UHPLC-MS / MS和CLC-MS分析甲酸铵和甲醇流动相的洗脱模式。两种技术均在速度,灵敏度,选择性和分离度方面与常规LC-MS / MS进行了比较。通过固相萃取(SPE)萃取水样。由18种化合物计算出的两个浓度水平(6和60ngL〜(-1))下的平均绝对回收率分别为:77±12(s)和82±12(s)。每种全氟化合物的相对标准偏差(RSD)均低于16%。获得的结果表明,UHPLC-MS / MS和CLC-MS可以测定水样品中的全氟化合物,同时具有令人满意的灵敏度和分辨率,并减少了分析时间。因此,与使用HPLC-MS / MS相比,这两种技术都用于分析水样以确定低浓度水平和较短分析时间的目标分析物。两种技术在95%置信水平下均获得了相似的统计值。已检测到几种化合物,但全氟辛酸(PFOA)(分别通过UHPLC-MS / MS和CLC-MS测得的浓度为171ngL〜(-1)和148ngL〜(-1))。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号