首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts. Determination of polybrominated diphenyl ethers by gas chromatography-tandem mass spectrometry
【24h】

Dispersive solid-phase extraction as a simplified clean-up technique for biological sample extracts. Determination of polybrominated diphenyl ethers by gas chromatography-tandem mass spectrometry

机译:分散固相萃取作为生物样品提取物的简化净化技术。气相色谱-串联质谱法测定多溴联苯醚

获取原文
获取原文并翻译 | 示例
           

摘要

Dispersive solid-phase extraction (DSPE) is proposed for the first time as a simplified, fast and low cost clean-up technique of biological sample extracts for polybrominated diphenyl ethers (PBDEs) determination. The combination of a traditional extraction technique, such as ultrasound-assisted leaching (USAL) with DSPE was successfully applied for sample preparation prior to gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. The analytes were first extracted from 1g homogenized sample in n-hexane:dichloromethane (8:2) by applying USAL technique and further cleaned-up using DSPE with 0.20gC_(18)-silica as sorbent material. Different solvent mixtures, sorbent type and amount, and lipid digestion procedures were evaluated in terms of clean-up and extraction efficiency. Under optimum conditions, the method detection limits (MDLs) for PBDEs, calculated as three times the signal-to-noise ratio (S/N) were within the range 9-44pgg-1 wet weight. The calibration graphs were linear within the concentration range of 53-500,000pgg~(-1), 66-500,000pgg-1, 89-500,000pgg-1 and 151-500,000pgg-1 for BDE-47, BDE-100, BDE-99 and BDE-153, respectively; and the coefficient of determination (r2) exceeded 0.9992 for all analytes. The proposed methodology was compared with a reference solid-phase extraction technique. The applicability of the methodology for the screening of PBDEs has been demonstrated by analyzing spiked and real samples of biological nature (fish, egg and chicken) with different lipid content as well as reference material (WELL-WMF-01). Recovery values ranged between 75% and 114% and the measured concentrations in certified material showed a reasonable agreement with the certified ones. BDE-47, BDE-100 and BDE-99 were quantified in three of the seven analyzed samples and the concentrations ranged between 91 and 140pgg-1. In addition, this work is the first description of PBDEs detected in fish of Argentinean environment.
机译:首次提出了分散固相萃取(DSPE)作为生物样品提取物的简化,快速和低成本净化技术,用于测定多溴联苯醚(PBDEs)。在气相色谱-串联质谱分析(GC-MS / MS)之前,传统提取技术(如超声辅助浸出(USAL)与DSPE)的结合已成功用于样品制备。首先通过应用USAL技术从正己烷:二氯甲烷(8:2)中的1g均质样品中提取分析物,然后使用DSPE用0.20gC_(18)-硅胶作为吸附剂进一步净化。根据净化和萃取效率评估了不同的溶剂混合物,吸附剂类型和数量以及脂质消化程序。在最佳条件下,PBDE的方法检测限(MDL)计算为信噪比(S / N)的三倍,在9-44pgg-1湿重范围内。 BDE-47,BDE-100,BDE的浓度范围在53-500,000pgg〜(-1),66-500,000pgg-1、89-500,000pgg-1和151-500,000pgg-1的浓度范围内是线性的-99和BDE-153;所有分析物的测定系数(r2)均超过0.9992。将所提出的方法与参考固相萃取技术进行了比较。通过分析加标的和真实的具有不同脂质含量的生物性质样品(鱼,蛋和鸡)以及参考材料(WELL-WMF-01),证明了该方法用于多溴二苯醚筛查的适用性。回收率介于75%至114%之间,并且经认证的材料中的测得浓度与经认证的材料之间存在合理的一致性。在七个分析样品中的三个样品中,对BDE-47,BDE-100和BDE-99进行了定量,浓度范围为91至140pgg-1。此外,这项工作是对阿根廷环境鱼类中检测到的多溴二苯醚的首次描述。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号