...
首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters
【24h】

In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters

机译:管内固相微萃取通过阀模式与毛细管LC-DAD偶联:提高了对几个完整水域中多残留有机污染物分析的可检测性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens. organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl-5% phenyl substituted backbone, 80 cm x 0.32 mm id., 3 mu m film thickness) in the injection valve to capillary liquid chromatography with diode array detection. A comparative study between the IT-SPME manifold and a column-switching device using a C-18 column (35 mm x 0.5 mm i.d., 5 mu m particle size) has been performed. The IT-SPME procedure was optimal, it allows reaching limits of detection (LODs) between 0.008 and 0.2 mu g/L. No matrix effect was found and recoveries between 70 and 116% were obtained. The precision of the method was good, and the achieved intra- and inter-day variation coefficients were between 2 and 30%. This procedure has been applied to the screening analysis of 28 compounds in whole waters from several points of the Mediterranean coast (Valencia Community, Spain).
机译:已经开发了一种简单快速的毛细管色谱法,用于鉴定和定量真实水样品中亚ppb级的有机污染物。这项研究包括了主要的农药(有机卤素,有机磷和有机氮化合物),一些碳氢化合物(多环芳烃),邻苯二甲酸盐和一些酚,例如苯酚和双酚A(内分泌干扰物)。该过程基于使用常规GC毛细管柱(95%甲基-5%苯基取代的主链,内径80 cm x 0.32 mm,膜厚3μm)的管内固相微萃取(IT-SPME)偶联方法。 )在进样阀中以毛细管液相色谱法用二极管阵列检测。在IT-SPME歧管和使用C-18色谱柱(内径35 mm x 0.5 mm,粒径5μm)的色谱柱切换装置之间进行了比较研究。 IT-SPME程序是最佳的,它可以达到0.008至0.2μg / L的检测限(LOD)。未发现基质效应,回收率在70%到116%之间。该方法的精度良好,并且日内和日间变化系数达到2%至30%。该程序已用于从地中海沿岸几个地点(西班牙巴伦西亚社区)对全水中的28种化合物进行筛选分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号