Nanoporous polyethersulfone (PES) membranes are widely used in dialysis systems due to their permeability and diffusion characteristics. However, PES membranes lack blood compatibility, which influences their permeability performance when employed in blood contact devices. Parylene film was deposited on a PES membrane surface and the membrane permeability and blood compatibility were investigated by long-term blood diffusion testing. After 28 days of testing, 90% of a bare PES membrane was covered with platelets, while the parylene film coated PES membrane had improved biocompatibility with a platelet coverage of only 20-30%. The permeability of the bare PES membrane significantly declined during the first 7 days of the blood diffusion and became stable after 8 days. In contrast, the permeability of the parylene film coated PES membrane exhibited more consistent performance during the entire test. Thus, parylene film coating on PES membrane has potential for application in hemodialysis systems.
机译:纳米多孔聚醚砜(PES)膜由于其渗透性和扩散特性而广泛用于透析系统。然而,PES膜缺乏血液相容性,当用于血液接触装置时会影响其渗透性能。聚对二甲苯膜沉积在PES膜表面,并通过长期血液扩散测试研究了膜的渗透性和血液相容性。经过28天的测试,90%的裸露PES膜被血小板覆盖,而聚对二甲苯膜涂覆的PES膜具有更好的生物相容性,血小板覆盖率仅为20%至30%。裸露的PES膜的渗透性在血液扩散的前7天显着下降,并在8天后变得稳定。相反,涂有聚对二甲苯膜的PES膜的渗透性在整个测试过程中表现出更一致的性能。因此,PES膜上的聚对二甲苯膜涂层具有在血液透析系统中应用的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号