Purpose: Technical modifications of the 120 W lithium-triborate laser have been implemented to increase power output, and prevent laser fiber degradation and loss of power output during laser vaporization of the prostate. However, visible alterations at the fiber tip and the subjective impression of decreasing ablative effectiveness during lithium-triborate laser vaporization indicate that delivering constantly high laser power remains a relevant problem. Thus, we evaluated the extent of laser fiber degradation and loss of power output during 120 W lithium-triborate laser vaporization of the prostate.Materials and Methods: We investigated 46 laser fibers during routine 120 W lithium-triborate laser vaporization in 35 patients with prostatic bladder outflow obstruction. Laser beam power was measured at baseline and after the application of each 25 kJ during laser vaporization. Fiber tips were microscopically examined after the procedure.Results: Mild to moderate degradation at the emission window occurred in all fibers, associated with a loss of power output. A steep decrease to a median power output of 57.3% of baseline was detected after applying the first 25 kJ. Median power output at the end of the defined 275 kJ lifespan of the fibers was 48.8%.Conclusions: Despite technical refinements of the 120 W lithium-triborate laser fiber degradation and significantly decreased power output are still detectable during the procedure. Laser fibers are not fully appropriate for the high power delivery of the new system. There is still potential for further improvement in the laser performance.
机译:目的:已经对120 W三硼酸锂激光器进行了技术改造,以增加功率输出,并防止激光纤维降解和前列腺激光汽化过程中功率输出的损失。然而,在三硼酸锂激光汽化过程中,纤维尖端的可见变化以及烧蚀效率降低的主观印象表明,持续提供高激光功率仍然是一个相关问题。因此,我们评估了在120 W前列腺三硼酸锂激光汽化过程中激光纤维降解的程度和功率输出的损失。材料与方法:我们在35例前列腺癌患者的常规120 W三硼酸锂激光汽化过程中研究了46根激光纤维。膀胱流出道梗阻。在基线和激光汽化过程中每施加25 kJ后测量激光束功率。手术后用显微镜检查纤维尖端。结果:所有纤维在发射窗口处均出现轻度至中度降解,这与功率输出损失有关。在施加最初的25 kJ后,检测到中值功率输出急剧下降至基线的57.3%。在规定的275 kJ寿命结束时,功率输出的中位数为48.8%。结论:尽管在工艺上对120 W三硼酸锂激光光纤的性能进行了技术改进,但仍然可以检测到功率明显降低。激光光纤并不完全适合新系统的高功率传输。激光性能仍有进一步提高的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号