PURPOSE: Prior study has shown that holmium:YAG laser fiber performance differs among manufacturers. We determined the performance and threshold for failure of 24 commercially available holmium:YAG laser fibers. MATERIALS AND METHODS: Single use and reusable fibers were tested in small (150 to 300 microm) and medium (300 to 400 microm) core diameter sizes. All fibers were evaluated for flexibility, failure threshold and true fiber diameter. Flexibility was measured by maximally deflecting a Stryker U-500 ureteroscope with the fiber in the working channel. The diameter of each fiber was measured by a digital micrometer. The failure threshold was assessed by bending the fibers to 180 degrees, beginning with a radius of 1.25 cm. A VersaPulse 100 W holmium:YAG laser was operated at 1.2 J and 10 Hz for 1 minute or until fiber fracture. The bend radius was decreased in 0.25 cm increments and testing was repeated until a minimum bend radius of 0.5 cm was attained or until the fiber failed. RESULTS: Of the small core fibers the SureFlex LLF-150 and LLF-273, OptiLite SMH1020F and Dornier LG Super 270 had the highest threshold for failure. The Accuflex 200 had the lowest failure threshold failing at the largest bend radius (1.75 cm). Of the medium core fibers the SureFlex LLF-365, Accuflex 365 and Lumenis SL 365 had the highest failure threshold, while the Dornier LG 400 and Lumenis EZ SL 365 were the lowest. The reusable Lumenis 365 fiber had a higher failure threshold than the single use Lumenis 365 fiber. CONCLUSIONS: Commercially available holmium:YAG laser fibers differ significantly in their performance characteristics.
机译:目的:先前的研究表明:YAG激光光纤的性能在制造商之间是不同的。我们确定了24种市售:YAG激光光纤的性能和失效阈值。材料和方法:一次性和可重复使用的纤维分别以小(150至300微米)和中等(300至400微米)的芯径尺寸进行了测试。评价所有纤维的柔韧性,破坏阈值和真实纤维直径。通过使光纤在工作通道中的Stryker U-500输尿管镜最大偏转来测量柔韧性。每根纤维的直径通过数字千分尺测量。通过将纤维弯曲到180度(从半径1.25厘米开始)来评估破坏阈值。将VersaPulse 100 W m:YAG激光器以1.2 J和10 Hz的频率运行1分钟或直至光纤断裂。弯曲半径以0.25 cm的增量减小,并重复测试,直到达到0.5 cm的最小弯曲半径或直到光纤失效为止。结果:在小型纤芯中,SureFlex LLF-150和LLF-273,OptiLite SMH1020F和Dornier LG Super 270的故障阈值最高。 Accuflex 200在最大弯曲半径(1.75厘米)处具有最低的失效阈值。在中芯光纤中,SureFlex LLF-365,Accuflex 365和Lumenis SL 365的故障阈值最高,而Dornier LG 400和Lumenis EZ SL 365的故障阈值最低。可重复使用的Lumenis 365光纤的故障阈值高于一次性使用的Lumenis 365光纤。结论:市售的:: YAG激光光纤的性能特征差异很大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号