首页> 外文期刊>Critical reviews in physical and rehabilitation medicine >Osteoanatomy of the Adult Humerus for Rehabilitative Assessment: Referenced to. the NIH Visible Human Project (NIH-VHP)
【24h】

Osteoanatomy of the Adult Humerus for Rehabilitative Assessment: Referenced to. the NIH Visible Human Project (NIH-VHP)

机译:成人肱骨的骨解剖以进行康复评估:参见。美国国立卫生研究院可见人类计划(NIH-VHP)

获取原文
获取原文并翻译 | 示例

摘要

A Reference-Humeras model was developed for rehabilitation applications based on the NIH Visible Human Project. The model was comprised of (i) a physical model (H-VHP) and (ii) the associated 3D computational geometry. Anatomic characterization and evaluation with published human humeral anatomic data provide anatomic validation for clinical, rehabilitative applicability. Using CT-based 3D computational methods, geometric definitions of specific humeral landmarks were established by sequentially defining best fits, axes, and coordinate systems. Key surgical osteoanatomy parameters were then determined. Measured whole bone parameters included length and retroversion. Proximal articular parameters included articular surface radius, humeral head height, and humeral head medial, posterior, and total offsets. Proximal nonarticular parameters include inclination, head to greater tuberosity height, greater tuberosity width, and lateral offset, and lesser tuberosity anterior offset. Distal parameters included trochlear sulcus and capitellum radii of curvature, and distal flexion-extension axis anterior and medial offsets. All measured anatomic parameters of the Reference-Humerus lay within or very close to respective ranges that were derived by pooling data from published studies on human (cadaveric and live) humeri. Based on measurements, the Reference-Humeras has application as a rehabilitative and surgical tool to analyze proximal (shoulder) and distal (elbow) joint loading, and assistive device loads (walkers, crutches, canes, wheelchairs), and to develop accurate numerical models as an adjunct to presurgical planning and postsurgical follow-up (humeral nails, shoulder and elbow arthroplasty implants).
机译:基于NIH可见人类项目,为康复应用开发了Reference-Humeras模型。该模型由(i)物理模型(H-VHP)和(ii)相关的3D计算几何组成。已发表的人体肱骨解剖学数据进行的解剖学表征和评估为临床,康复适用性提供了解剖学验证。使用基于CT的3D计算方法,通过依次定义最佳拟合,轴和坐标系,可以建立特定肱骨界标的几何定义。然后确定关键的手术骨解剖参数。测得的全骨参数包括长度和逆行。近端关节参数包括关节表面半径,肱骨头高度以及肱骨头内侧,后侧和总偏移量。近端非关节参数包括倾斜度,朝向更大的结节高度,更大的结节宽度和横向偏移以及较小的结节前向偏移。远端参数包括滑车沟和前庭曲率半径,以及远端屈伸轴的前后偏移。参考肱骨的所有测得的解剖学参数都在各自的范围内或非常接近,这些范围是通过合并已发表的有关人类(尸体和活体)肱骨研究的数据得出的。根据测量,Reference-Humeras可作为康复和外科手术工具,用于分析近端(肩部)和远端(肘部)关节负荷以及辅助装置负荷(助行器,拐杖,手杖,轮椅),并开发精确的数值模型作为术前计划和术后随访(肱骨钉,肩及肘关节置换植入物)的辅助手段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号