Reproducibility of thickness measurements of macular inner retinal layers using SD-OCT with or without correction of ocular rotation

机译:使用SD-OCT校正或不校正眼球旋转可测量黄斑内视网膜层厚度的可重复性

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE. To evaluate the intervisit reproducibility of spectral-domain optical coherence tomography (SD-OCT) measurement of the macular retinal nerve fiber layer thickness (mRNFLT); combined ganglion cell layer and inner plexiform layer (GCL+IPL) thickness; and ganglion cell complex (GCC) thicknesses (sum of mRNFLT and GCL+IPL thicknesses) compared with that of circumpapillary RNFLT (cpRNFLT) and the effect of ocular rotation on reproducibility. METHODS. SD-OCT imaging was performed twice on different days in one eye of 58 normal subjects and 73 glaucoma patients. The reproducibility was evaluated for the entire 4.8-mm×4.8-mm macular area and subareas (upper and lower halves, 2×2, 4×4, and 8×8 grids), and the 3608, upper, and lower halves mean cpRNFLT with and without correction of ocular rotation. RESULTS. The coefficients of variation (CVs) of GCL+IPL and GCC thickness measurements averaged below 1.0% for the entire and upper and lower half macular areas, and below 4.2% in the macular subareas in normal and glaucoma eyes, which were significantly smaller (P < 0.001) than those of mRNFLT measurements in the same areas of the same eyes. The CVs of mRNFLT measurements were significantly smaller than those of the cpRNFLT only in the lower half mean area in normal eyes. The reproducibility was minimally affected by correction of ocular rotation or presence of glaucoma. CONCLUSIONS. The reproducibility of the macular (GCL+IPL) and GCC thickness measurements was better than that of mRFNLT and cpRNFLT in normal and glaucoma eyes and minimally affected by correction of ocular rotation.
机译:目的。评估光谱域光学相干断层扫描(SD-OCT)测量黄斑区视网膜神经纤维层厚度(mRNFLT)的间断重现性;神经节细胞层和内丛状层(GCL + IPL)的总厚度;神经节细胞复合物(GCC)厚度(mRNFLT和GCL + IPL厚度的总和)与环乳头RNFLT(cpRNFLT)的厚度以及眼球旋转对重现性的影响。方法。在58名正常受试者和73名青光眼患者的一只眼睛中,SD-OCT成像在不同的日期进行了两次。对整个4.8mm×4.8mm的黄斑区域和子区域(上半部分和下半部分,2×2、4×4和8×8网格)的可重复性进行了评估,而3608,上半部分和下半部分均表示cpRNFLT有和没有矫正眼球旋转。结果。 GCL + IPL和GCC厚度测量的变异系数(CV)在整个和上下半部黄斑区域平均低于1.0%,在正常和青光眼眼的黄斑区域中低于4.2% <0.001),而不是同一只眼睛相同区域的mRNFLT测量值。 mRNFLT测量值的CV仅在正常眼睛的下半部平均区域显着小于cpRNFLT。眼球旋转或青光眼的矫正对再现性的影响很小。结论。在正常和青光眼中,黄斑区(GCL + IPL)和GCC厚度测量的可重复性优于mRFNLT和cpRNFLT,并且受眼球旋转矫正的影响最小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号