The calibration of misalignment aberrations is a key issue in the testing of high-numerical-aperture spherical surfaces, and it is hard to separate the high-order aberrations introduced by misalignment from the measured data. The traditional calibration method is still applicable in the case of only wave-front tilt, but no longer effective in the existence of defocus. A calibration technique based on the wave-front difference is proposed to calibrate the misalignment aberrations in the presence of wavefront defocus, and it can be carried out without foreknowledge of the spherical surface under test. With the wavefront difference method, the calibration needs two separate measurements to separate the high-order aberrations. Both the computer simulation and experiments with the ZYGO interferometer have been carried out to validate the proposed calibration technique, with the accuracies better than 0.0005lambda RMS and 0.0010lambda RMS achieved, respectively. The proposed calibration method provides a feasible way to lower the requirement on the adjustment in the measurement, while retaining good accuracy.
机译:失准像差的校准是测试高数值孔径球面的关键问题,并且很难从测量数据中分离出由失准引入的高阶像差。传统的校准方法仅在波前倾斜的情况下仍然适用,但在散焦的情况下不再有效。提出了一种基于波前差的校准技术,用于在存在波前散焦的情况下校准失准像差,并且该校准技术无需事先知道被测球面即可。使用波前差分法,校准需要两次单独的测量以分离高阶像差。进行了计算机模拟和ZYGO干涉仪的实验,以验证所提出的校准技术,其精度分别优于0.0005λRMS和0.0010λRMS。所提出的校准方法提供了一种可行的方式来降低对测量调整的要求,同时保持良好的精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号