首页> 外文期刊>Analytica chimica acta >Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride
【24h】

Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride

机译:高效液相色谱-电喷雾串联丹磺酰氯的高效液相色谱-电喷雾电离串联质谱法测定人血浆中的磷酸哌嗪

获取原文
获取原文并翻译 | 示例
       

摘要

This paper describes a novel method that combines dansyl chloride (DNS-CL) derivatization with high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) for the sensitive and selective determination of piperazine phosphate in human plasma. After addition of ondansetron hydrochloride as internal standard (IS), piperazine phosphate was derivatized and then extracted with ethyl acetate. After being evaporated and reconstituted, the sample was analyzed using LC-ESI/MS/MS. Separation was achieved using an Agilent ZORBAX SB-C_(18) (150mm x 2.1 mm I.D., 3.5μm) column and isocratic elution with 10mM ammonium acetate solution (pH 3.0)-methanol (50: 50, v/v). Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 320→ 171 for DNS-CL-piperazine phosphate and m/z 294→ 170 for the IS. The method was fully validated for its selectivity, sensitivity, linearity, precision, accuracy, recovery, matrix effect and stability. The coefficient (r) of piperazine phosphate with a linear range of 0.1-15 μgm L~(-1) was 0.9974-0.9995. The limit of detection and lower limit of quantification in human plasma were 0.01 and 0.1 μg mL~(-1), respectively. The validated LC-ESI/MS/MS method has been successfully applied to a bioequivalence study of piperazine phosphate trochiscus in Chinese healthy male volunteers.
机译:本文介绍了一种将丹酰氯(DNS-CL)衍生化与高效液相色谱-电喷雾电离串联质谱(LC-ESI / MS / MS)相结合的新方法,用于灵敏和选择性地测定人血浆中的磷酸哌嗪。加入盐酸恩丹西酮作为内标(IS)后,磷酸哌嗪衍生化,然后用乙酸乙酯萃取。蒸发并重构后,使用LC-ESI / MS / MS分析样品。使用Agilent ZORBAX SB-C_(18)(150mm x 2.1 mm I.D.,3.5μm)色谱柱并用10mM乙酸铵溶液(pH 3.0)-甲醇(50:50,v / v)等度洗脱实现分离。使用正离子运行的电喷雾电离(ESI)接口和选定的反应监测(SRM)模式在三重四极杆质谱仪上进行检测,其中DNS-CL-哌嗪磷酸盐的产物离子跃迁m / z 320→171和IS的m / z 294→170。该方法的选择性,灵敏度,线性,精密度,准确性,回收率,基质效应和稳定性均得到了充分验证。线性范围为0.1-15μgmL〜(-1)的磷酸哌嗪系数(r)为0.9974-0.9995。人血浆中的检出限和定量下限分别为0.01和0.1μgmL〜(-1)。经过验证的LC-ESI / MS / MS方法已成功应用于中国健康男性志愿者中磷酸哌嗪曲风的生物等效性研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号