An improved and novel sample preparation method for 241 Am analysis by inductively coupled plasma sector field mass spectrometry has been developed.The procedure involves a selective CaF2 pre-concentration followed by an extraction chromatographic separation using TRU~(?)resin.The achieved absolute detection limit of 0.86 fg(0.11 mBq)is comparable to that of alpha spectrometry(0.1 mBq)and suitable for low-level environmental measurements.Analysis of different kinds of environmental standard reference materials(IAEA-384-Fangataufa lagoon sediment,IAEA-385-Irish Sea sediment and IAEA-308-Mixed seaweed from the Mediterranean Sea)and alpha spectrometry were used to validate the procedure.The chemical recovery of sample preparation ranged between 72 and 94%.The results obtained are in good agreement with reference values and those measured by alpha spectrometry.The proposed method offers a rapid and less labor-intensive possibility for environmental241 Am analysis than the conventionally applied radioanalytical techniques.
机译:提出了一种改进的新颖的样品制备方法,用于电感耦合等离子体扇形场质谱分析241 Am,方法包括选择性的CaF2预浓缩,然后使用TRU〜(?)树脂进行萃取色谱分离,从而实现了绝对检测极限浓度为0.86 fg(0.11 mBq),与α光谱法(0.1 mBq)相当,适用于低水平环境测量。分析各种环境标准参考物质(IAEA-384-Fangataufa泻湖沉积物,IAEA-385-用爱尔兰海沉积物和来自地中海的IAEA-308混合海藻)和α光谱法验证了该程序,样品制备的化学回收率在72%至94%之间,所得结果与参考值和那些均与参考值良好吻合所提出的方法为环境241 Am分析提供了比常规ap更快,更省力的可能性运用了放射分析技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号