首页> 外文期刊>Analytical chemistry >Flowing Liquid Anode Atmospheric Pressure Glow Discharge as an Excitation Source for Optical Emission Spectrometry with the Improved Detectability of Ag, Cd, Hg, Pb, Tl, and Zn
【24h】

Flowing Liquid Anode Atmospheric Pressure Glow Discharge as an Excitation Source for Optical Emission Spectrometry with the Improved Detectability of Ag, Cd, Hg, Pb, Tl, and Zn

机译:改进的Ag,Cd,Hg,Pb,Tl和Zn的可检测性的液态阳极阳极大气压辉光放电作为光发射光谱的激发源

获取原文
获取原文并翻译 | 示例
       

摘要

A novel atmospheric pressure glow discharge generated in contact with a flowing liquid anode (FLA-APGD) was developed as the efficient excitation source for the optical emission spectrometry (OES) detection. Differences in the appearance and the electrical characteristic of the FLA-APGD and a conventional system operated with a flowing liquid cathode (FLC-APGD) were studied in detail and discussed. Under the optimal operating conditions for the FLA-APGD, the emission from the analytes (Ag, Cd, Hg, Pb, Tl, and Zn) was from 20 to 120 times higher as compared to the FLC-APGD. Limits of detections (LODs) established with a novel FLA-APGD system were on average 20 times better than those obtained for the FLC-APGD. A further improvement of the LODs was achieved by reducing the background shift interferences and, as a result, the LODs for Ag, Cd, Hg, Pb, Tl, and Zn were 0.004, 0.040, 0.70, 1.7, 0.035, and 0.45 mu g L-1, respectively. The precision of the FLA-APGD-OES method was evaluated to be within 2-5% (as the relative standard deviation of the repeated measurements). The method found its application in the determination of the content of Ag, Cd, Hg, Pb, Tl, and Zn in a certified reference material (CRM) of Lobster hepatopancreas (TORT-2), four brass samples as well as mineral water and tea leaves samples spiked with the analytes. In the case of brass samples, a reference method, i.e., inductively coupled plasma optical emission spectrometry (ICP-OES) was used. A good agreement between the results obtained with FLA-APGD-OES and the certified values for the CRM TORT-2 as well as the reference values obtained with ICP-OES for the brass samples was revealed, indicating the good accuracy of the proposed method. The recoveries obtained for the spiked samples of mineral water and tea leaves were within the range of 97.5-102%.
机译:与流动的液体阳极(FLA-APGD)接触产生的新型大气压辉光放电被开发为光学发射光谱(OES)检测的有效激发源。详细研究了FLA-APGD的外观和电气特性与采用流动阴极的传统系统(FLC-APGD)的差异。在FLA-APGD的最佳操作条件下,分析物(Ag,Cd,Hg,Pb,Tl和Zn)的发射量是FLC-APGD的20至120倍。用新型FLA-APGD系统建立的检出限(LOD)平均比使用FLC-APGD获得的检出限平均高20倍。通过降低背景偏移干扰实现了LOD的进一步改善,结果,Ag,Cd,Hg,Pb,Tl和Zn的LOD为0.004、0.040、0.70、1.7、0.035和0.45μg L-1。经评估,FLA-APGD-OES方法的精度在2%至5%之内(作为重复测量的相对标准偏差)。该方法适用于测定龙虾肝胰腺(TORT-2),四个黄铜样品以及矿泉水和水的认证参考物质(CRM)中Ag,Cd,Hg,Pb,Tl和Zn的含量。茶叶样品中掺入了分析物。对于黄铜样品,使用参考方法,即电感耦合等离子体发射光谱法(ICP-OES)。结果表明,使用FLA-APGD-OES获得的结果与CRM TORT-2的认证值以及使用ICP-OES获得的黄铜样品参考值之间具有良好的一致性,表明了该方法的准确性。加标的矿泉水和茶叶样品的回收率在97.5-102%的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号