首页> 外文期刊>Analytical chemistry >Triple-Quadrupole Inductively Coupled Plasma-Mass Spectrometry with a High-Efficiency Sample Introduction System for Ultratrace Determination of Cs-135 and Cs-137 in Environmental Samples at Femtogram Levels
【24h】

Triple-Quadrupole Inductively Coupled Plasma-Mass Spectrometry with a High-Efficiency Sample Introduction System for Ultratrace Determination of Cs-135 and Cs-137 in Environmental Samples at Femtogram Levels

机译:高效液相引入系统的三重四极杆电感耦合等离子体质谱法在痕量示踪水平上超痕量测定环境样品中的Cs-135和Cs-137

获取原文
获取原文并翻译 | 示例
       

摘要

High yield fission products, Cs-135 and Cs-137, have entered the environment as a result of anthropogenic nuclear activities. Analytical methods for ultratrace measurement of Cs-135 and Cs-137 are required for environmental geochemical and nuclear forensics studies. Here we report a highly sensitive method combining a desolvation sample introduction system (APEX-Q) with triple-quadrupole inductively coupled plasma mass spectrometry (AEPX-ICPMS/MS) for the determination of Cs-135 and Cs-135/Cs-137 isotope ratio at femtogram levels. Using this system, we introduced only selected ions into the collision/reaction cell to react with N2O, significantly reducing the isobaric interferences (Ba-135(+) and Ba-137(+)) and polyatomic interferences ((MoAr+)-Mo-95,97-Ar-40, (SnO+)-Sn-119-O-16, and (SbO+)-Sb-121-O-16). Compared to the instrument setup of ICPMS/MS, the APEX-ICPMS/MS enables a 10-fold sensitivity increase. In addition, an effective chemical separation scheme consisting of ammonium molybdophosphate (AMP) Cs-selective adsorption and two-stage ion-exchange chromatographic separation was developed to remove major matrix and interfering elements from environmental samples (10-40 g). This separation method showed high decontamination factors (10(4)-10(7)) for major matrix elements (Al, Ca, K, Mg, Na, and Si) and interfering elements (Ba, Mo, Sb, and Sn). The high sensitivity of APEX-ICPMS/MS and the effective removal sample matrix allowed reliable analysis of Cs-135 and Cs-137 with extremely low detection limits (0.002 pg mL(-1) corresponding to 0.006 Bq mL(-1) Cs-137). The accuracy and applicability of the APEX-ICPMS/MS method was validated by analysis of seven standard reference materials (soils, sediment, and plants). For the first time, ultratrace determination of Cs-135 and Cs-135/Cs-137 isotope ratio at global fallout source environmental samples was achieved with the ICPMS technique.
机译:由于人为核活动,高产裂变产物Cs-135和Cs-137已进入环境。环境地球化学和核法证研究需要使用Cs-135和Cs-137超痕量测量的分析方法。在这里,我们报告了结合去溶剂化样品引入系统(APEX-Q)和三重四极杆电感耦合等离子体质谱仪(AEPX-ICPMS / MS)的高灵敏度方法,用于测定Cs-135和Cs-135 / Cs-137同位素在飞度图级别的比率。使用该系统,我们仅将选定的离子引入到碰撞/反应池中以与N2O反应,从而显着降低了等压干扰(Ba-135(+)和Ba-137(+))和多原子干扰((MoAr +)-Mo- 95,97-Ar-40,(SnO +)-Sn-119-O-16和(SbO +)-Sb-121-O-16)。与ICPMS / MS的仪器设置相比,APEX-ICPMS / MS可使灵敏度提高10倍。此外,开发了一种有效的化学分离方案,其中包括钼酸铵(AMP)Cs选择性吸附和两阶段离子交换色谱分离,以从环境样品(10-40 g)中去除主要基质和干扰元素。这种分离方法对主要基质元素(Al,Ca,K,Mg,Na和Si)和干扰元素(Ba,Mo,Sb和Sn)显示出较高的去污因子(10(4)-10(7))。 APEX-ICPMS / MS的高灵敏度和有效的去除样品基质可以对Cs-135和Cs-137进行可靠的分析,检测限极低(0.002 pg mL(-1)对应于0.006 Bq mL(-1)Cs- 137)。通过分析七种标准参考物质(土壤,沉积物和植物),验证了APEX-ICPMS / MS方法的准确性和适用性。 ICPMS技术首次实现了在全球辐射源环境样品中超痕量测定Cs-135和Cs-135 / Cs-137同位素比的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号