Electrochemical impedance spectroscopy is frequently used to characterize, optimize, and monitor ion selective membranes. However, because of the relatively high resistance of ion-selective membranes, their impedance spectra often contain artifacts that can cause misinterpretation. While in the high-frequency range artifacts are often readily identifiable by the occurrence of inductive features or negative resistances, artifacts are easy to overlook in the low-frequency range, where telltale characteristics are typically missing. Some artifacts can be avoided by the use of two-electrode cells, but this experimental design makes it hard to distinguish the impedance of the ion-selective membrane from that of the Real Impedance measuring electrodes. This work shows that experimental data can be analyzed accurately with the use of models that account for the capacitive leakage present in the reference channels of the impedance spectrometer. To test these models, valinomycin-doped K+-selective membranes were studied by electrochemical impedance spectroscopy with two-, three-, and four-electrode cells, using several measuring electrodes with low to high impedances. The models were found to correctly predict experimental data and provide an intuitive understanding of the cause of the impedance artifacts. This understanding can be applied to design electrochemical impedance spectroscopy experiments of ion-selective membranes with three- and four-electrode cells that minimize artifacts.
机译:电化学阻抗谱经常用于表征,优化和监测离子选择性膜。但是,由于离子选择膜的电阻较高,因此它们的阻抗谱通常包含可能引起误解的伪影。虽然在高频范围内通常可以通过电感性特征或负电阻的出现来识别伪影,但在低频范围内通常容易丢失信号特征,因此容易忽略伪影。通过使用两电极电池可以避免某些伪影,但是这种实验设计使得很难将离子选择膜的阻抗与实际阻抗测量电极的阻抗区分开。这项工作表明,使用模型可以准确地分析实验数据,该模型考虑了阻抗谱仪参考通道中存在的电容性泄漏。为了测试这些模型,使用具有低至高阻抗的多个测量电极,通过电化学阻抗谱,用两电极,三电极和四电极电池研究了掺杂有金霉素的K +选择膜。发现这些模型可以正确预测实验数据并提供对阻抗伪像原因的直观了解。这种理解可以用于设计具有三极和四极电池的离子选择膜的电化学阻抗谱实验,以最大程度地减少伪影。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号