首页> 外文期刊>Analytical chemistry >Fluorescent Ru(phen)_3~(2+)-Doped Silica Nanoparticles-Based ICTS Sensor for Quantitative Detection of Enrofloxacin Residues in Chicken Meat
【24h】

Fluorescent Ru(phen)_3~(2+)-Doped Silica Nanoparticles-Based ICTS Sensor for Quantitative Detection of Enrofloxacin Residues in Chicken Meat

机译:荧光Ru(phen)_3〜(2+)掺杂的二氧化硅纳米粒子ICTS传感器定量检测鸡肉中的恩诺沙星残留

获取原文
获取原文并翻译 | 示例
           

摘要

A Ru(phen)_3~(2+)-doped silica fluorescent nanoparticle (FN)-based immunochromatographic test strip (ICTS) sensor was developed for rapid, high sensitivity, easy to use, and low cost quantitative detection of enrofloxacin (ENR) residues in chicken meat. The fluorescence signal intensity of the FNs at the test line (FI_T) and control line (FI_C) was determined with a prototype of a portable fluorescent strip reader. Unique properties of Ru(phen)_3~(2+) doped silica nanoparticles (e.g., large Stokes shift, high emission quantum yield, and long fluorescence lifetime) were combined with the advantages of ICTS and an easy to make portable fluorescent strip reader. The signal was based on FI_T/FI_C ratio to effectively eliminate strip to strip variation and matrix effects. Various parameters that influenced the strip were investigated and optimized. Quantitative ENR detection with the FNs ICTS sensor using 80 μL sample took only 20 min, which is faster than the commercial ELISA kit (that took 90 min). The linear range of detection in chicken extract was established at 0.025-3.500 ng/mL with a half maximal inhibitory concentration at 0.22 ± 0.02 ng/mL. Using the optimized parameters, the limit of detection (LOD) for ENR using the FNs ICTS sensor was recorded at 0.02 ng/mL in chicken extract. This corresponds to 0.12 μg/kg chicken meat which is two (2) orders of magnitude better that the maximum residue limits (MRLs) imposed in Japan (10 μg/kg) and three (3) orders of magnitude better than those imposed in China. The intra- and inter-assay coefficient of variations (CVs) were 6.04% and 12.96% at 0.5 ng/mL, 6.92% and 12.61% at 1.0 ng/mL, and 6.66% and 11.88% at 2.0 ng/mL in chicken extract, respectively. The recoveries using the new FNs ICTS sensor from fifty (50) ENR-spiked chicken samples showed a highly significant correlation (R~2 = 0.9693) with the commercial enzyme-linked immunosorbent assay (ELISA) kit. The new FNs ICTS sensor is a simple, rapid, sensitive, accurate, and inexpensive quantitative detection of ENR residues in chicken meat and extracts.
机译:开发了Ru(phen)_3〜(2+)掺杂的二氧化硅荧光纳米粒子(FNS)免疫色谱测试条(ICTS)传感器,用于快速,高灵敏度,易于使用和低成本定量检测恩诺沙星(ENR)鸡肉中的残留物。使用便携式荧光条读取器的原型确定测试线(FI_T)和控制线(FI_C)上FN的荧光信号强度。结合Ru(phen)_3〜(2+)的二氧化硅纳米粒子的独特性能(例如大斯托克斯位移,高发射量子产率和长荧光寿命)与ICTS的优点和易于制造的便携式荧光条读取器相结合。该信号基于FI_T / FI_C比率,以有效消除条带之间的差异和矩阵效应。研究并优化了影响带钢的各种参数。使用FNs ICTS传感器使用80μL样品进行定量ENR检测仅需20分钟,比市售ELISA试剂盒(耗时90分钟)要快。鸡提取物中的线性检测范围确定为0.025-3.500 ng / mL,最大抑制浓度的一半为0.22±0.02 ng / mL。使用优化的参数,在鸡提取物中使用FNs ICTS传感器记录的ENR的检出限(LOD)为0.02 ng / mL。这相当于0.12μg/ kg鸡肉,比日本施加的最大残留限量(MRL)(10μg/ kg)高两(2)个数量级,比中国施加的最大残留限量(MRL)高三(3)个数量级。鸡提取物中的测定内和测定间变异系数(CV)在0.5 ng / mL时分别为6.04%和12.96%,在1.0 ng / mL时为6.92%和12.61%,在2.0 ng / mL时为6.66%和11.88% , 分别。使用新型FNs ICTS传感器从五十(50)个ENR加标的鸡样品中回收的结果与商业化酶联免疫吸附测定(ELISA)试剂盒具有高度相关性(R〜2 = 0.9693)。新型FNs ICTS传感器可对鸡肉和提取物中的ENR残留物进行简单,快速,灵敏,准确且廉价的定量检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号