We have recently developed a new mass spectrometry method, the STEP (statistical test of equivalent pathways) analysis that uses ion abundances in two tandem mass spectrometry experiments to obtain genealogy information about product ions present in mass spectra. The method requires minimal sample, and it can be performed using a conventional quadrupole ion trap mass spectrometer. To obtain genealogy information, STEP ratios are calculated by comparing the relative abundances of product ions in two MS/MS experiments. These ratios are directly related to the origin of the product ions. Product ions that result directly from the precursor ion always have STEP ratios that are <= 1. Ions that result from secondary fragmentation pathways have REP ratios that are significantly larger than the primary ions, based on a Q test of statistical significance. Consequently, the type (primary or secondary) of all the product ions in an MS/MS experiment can easily be identified in this analysis. The STEP method is applied herein to peptides and carbohydrates, and the STEP results are consistent with validation data for 95% of the ions in this study. This new method has many applications in carbohydrate and peptide analysis. It can be used to support mechanistic studies of peptide fragmentation, and it is useful for discriminating among various isomeric carbohydrates, without the need for reference standards. Several examples are presented to demonstrate the reliability of this method, and an example showing how the method benefits carbohydrate sequencing is also provided.
机译:我们最近开发了一种新的质谱方法,即STEP(等效路径的统计检验)分析,该方法在两个串联质谱实验中使用离子丰度来获取有关质谱图中存在的产物离子的谱学信息。该方法所需的样品最少,可以使用常规的四极离子阱质谱仪进行。为了获得家谱信息,可以通过比较两次MS / MS实验中产物离子的相对丰度来计算STEP比率。这些比率与产物离子的来源直接相关。根据统计显着性的Q检验,直接由前体离子产生的产物离子的STEP比率始终小于或等于1。由次级裂解途径产生的离子的REP比率明显大于初级离子。因此,在此分析中可以轻松确定MS / MS实验中所有产物离子的类型(主要或次要)。 STEP方法在此应用于肽和碳水化合物,STEP结果与本研究中95%离子的验证数据一致。这种新方法在碳水化合物和多肽分析中有许多应用。它可用于支持肽片段化的机理研究,可用于区分各种异构碳水化合物,而无需参考标准。给出了几个例子来说明该方法的可靠性,并提供一个例子,说明该方法如何使碳水化合物测序受益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号