摘要

We examined Cortisol Kit [TFB] for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit [TFB] and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r = 0.858, y = 1.86x + 38.2 (p < 0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 microliters of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit [TFB] was very convenient for its easy assay procedure and short incubation.
机译:我们检查了皮质醇试剂盒[TFB]以直接测定尿皮质醇。并检查该试剂盒中尿皮质醇值乘以稀释倍数。皮质醇试剂盒[TFB]与另一种直接检测尿皮质醇的试剂盒Chemilumi ACS-Cortisol II之间的皮质醇水平(46个尿样)的相关系数为r = 0.858,y = 1.86x + 38.2(p < 0.001)。尽管相关系数良好,但每个尿液样本的两种皮质醇水平之间仍存在差异。从标准曲线获得的尿皮质醇值加上50微升的零标准溶液,是从包装插入物中的标准曲线获得的值的50-80%。这些结果表明,两种直接检测试剂盒对尿皮质醇的抗体的特异性可能互不相同,并且与必不可少的乘以1.09(由于仅向尿液样品中添加零标准物而导致的稀释倍数)虽然是必不可少的对于尿液样品要加零标准。皮质醇试剂盒[TFB]易于检测且易于孵育,非常方便。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号