首页> 外文期刊>Journal of Research of the National Institute of Standards and Technology >Double-Focusing Thermal Triple-Axis Spectrometer at the NCNR
【24h】

Double-Focusing Thermal Triple-Axis Spectrometer at the NCNR

机译:NCNR的双焦点热三轴光谱仪

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The new thermal triple-axis spectrometer at the NIST Center for Neutron Research (NCNR) is located at the BT-7 beam port. The 165 mm diameter reactor beam is equipped with a selection of Soller collimators, beam-limiters, and a pyrolytic graphite (PG) filter to tailor the beam for the dual 20×20 cm~2 double-focusing monochromator system that provides monochromatic fluxes exceeding 10~8 n/cm~2/s onto the sample. The two monochromators installed are PG(002) and Cu(220), which provide incident energies from 5 meV to above 500 meV. The computer controlled analyzer system offers six standard modes of operation, including a diffraction detector, a position-sensitive detector (PSD) in diffraction mode, horizontal energy focusing analyzer with detector, a Q-E mode employing a flat analyzer and PSD, a constant-E mode with the analyzer crystal system and PSD, and a conventional mode with a selection of S?ller collimators and detector. Additional configurations for specific measurement needs are also available. This paper discusses the capabilities and performance for this new state-of-the-art neutron spectrometer.
机译:NIST中子研究中心(NCNR)的新型热三轴光谱仪位于BT-7光束端口。直径165 mm的反应器光束配备了一系列Soller准直仪,光束限制器和热解石墨(PG)滤光片,可为双20×20 cm〜2双焦点单色仪系统定制光束,该单色仪提供的单色光通量超过样品上10〜8 n / cm〜2 / s安装的两个单色仪是PG(002)和Cu(220),它们提供从5 meV到500 meV以上的入射能量。计算机控制的分析仪系统提供六种标准操作模式,包括衍射检测器,处于衍射模式的位置敏感检测器(PSD),带有检测器的水平能聚焦分析仪,采用平面分析仪和PSD的QE模式,恒定E分析仪晶体系统和PSD的常规模式,以及选择了斯勒准直仪和检测器的常规模式。还可以提供满足特定测量需求的其他配置。本文讨论了这种新型的最新中子光谱仪的功能和性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号