首页> 外文期刊>Diabetes technology & therapeutics >Assessing the Quality of Publications Evaluating the Accuracy of Blood Glucose Monitoring Systems
【24h】

Assessing the Quality of Publications Evaluating the Accuracy of Blood Glucose Monitoring Systems

机译:评估出版物质量,评估血糖监测系统的准确性

获取原文
获取原文并翻译 | 示例
           

摘要

Many studies determine the performance of blood glucose monitoring (BG) systems. Correct evaluation is, however, complex, and apparent contradiction of results creates confusion. This study aimed to provide an overview of frequently made errors and to develop easy-to-use checklists to verify the quality of such studies. Building on the work from Mahoney and Ellison and subsequent re-evaluation, study designs of accuracy studies were assessed, and best practice and internationally accepted norms were determined. Key issues were collated, and two simplified checklists were developed: one for the assessment of analytical accuracy studies and a second for guidance with studies assessing the influence of interferences. The checklists have been used in a feasibility study with 20 representative studies selected from a literature search between 2007 and 2012. This check revealed that limitations in the designs and methods of studies assessing the performance of BG systems are common. The use of the accuracy checklist with the 20 representative studies showed that only 20% were in agreement with most of the issues deemed important and that 40% showed clear nonconcordance with ISO 15197. The use of the interference checklist showed that only 50% of the publications were in good agreement with the quality checks. In agreement with previous studies, which concluded many evaluations are performed poorly and present questionable conclusions, the use of these checklists demonstrated that few publications adhered to international guidelines and recommendations. Taking this into consideration, it becomes obvious that the publications must be examined in more detail to establish their quality and the validity of conclusions drawn.
机译:许多研究确定了血糖监测(BG)系统的性能。但是,正确的评估是复杂的,结果的明显矛盾会造成混乱。本研究旨在概述常见错误,并开发易于使用的清单以验证此类研究的质量。基于Mahoney和Ellison的工作以及随后的重新评估,对准确性研究的研究设计进行了评估,并确定了最佳实践和国际公认的准则。整理了关键问题,并制定了两个简化的清单:一个清单用于评估分析准确性研究,第二个清单用于指导评估干扰影响的研究。该清单已用于可行性研究,从2007年至2012年从文献检索中选择了20项代表性研究。这项检查表明,评估BG系统性能的研究设计和方法存在局限性。在20项代表性研究中使用准确性检查表表明,只有20%的人与大多数被认为重要的问题相符,而40%的人明确表示不符合ISO15197。干扰检查表的使用表明,只有50%出版物与质量检查非常吻合。与先前的研究一致的是,先前的研究得出的结论是,许多评估均表现不佳且得出可疑的结论,这些清单的使用表明,很少有出版物遵循国际准则和建议。考虑到这一点,很明显,必须对出版物进行更详细的检查,以确定其质量和得出结论的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号