...
首页> 外文期刊>Journal of Virological Methods >Comparative evaluation of two automated systems for nucleic acid extraction of BK virus: NucliSens easyMAG versus BioRobot MDx
【24h】

Comparative evaluation of two automated systems for nucleic acid extraction of BK virus: NucliSens easyMAG versus BioRobot MDx

机译:两种用于BK病毒核酸提取的自动化系统的比较评估:NucliSens easyMAG与BioRobot MDx

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to compare the performance of two automated nucleic acid extraction systems. Specifically, the NucliSens easyMAG system (bioMerieux, Marcy I'Etoile, France), which incorporates magnetic bead technology, was compared with the BioRobot MDx system (Qiagen GmbH, Hilden, Germany), which uses a silica membrane-based method of nucleic acid extraction. Nucleic acids from the BK virus (BKV DNA) were extracted from 98 plasma and 57 urine specimens using the Real-Q BKV quantitation kit (Biosewoom, Seoul, Korea). Failed PCR was defined as negative BKV DNA results having more than 36 threshold cycles of the internal control by the manufacturer's instruction. The PCR failure rate of nucleic acids isolated from plasma samples using the MDx system was similar to that of plasma samples processed using the easyMAG system (2.0% and 3.1%, respectively). The PCR failure rate of nucleic acids isolated from urine samples using the MDx system was higher than that of urine samples processed using the easyMAG system (33.3% and 12.5%, respectively). These data suggest that the PCR inhibitors present in urine specimens are removed more efficiently by the easyMAG system. Among amplified specimens, the discordant results obtained from the two systems revealed that the BKV DNA load ranged from 2.3 log(10) copies/mL to 4.6 log(10) copies/mL of the 25 urine specimens that yielded BKV DNA by both extraction systems, 15 specimens (60.0%) yielded higher BKV DNA loads by the easyMAG system, indicating that the easyMAG system extracted nucleic acid more efficiently than did the MDx system. In conclusion, the easyMAG method outperformed the MDx method when used to extract BKV DNA from urine samples. Magnetic bead-based extraction methods such as the easyMAG system are therefore preferable for the quantitation of viral DNA in urine.
机译:这项研究的目的是比较两种自动核酸提取系统的性能。具体而言,将结合了磁珠技术的NucliSens easyMAG系统(bioMerieux,法国Marcy I'Etoile)与BioRobot MDx系统(Qiagen GmbH,德国希尔登,德国)进行了比较,后者使用了基于硅胶膜的核酸方法萃取。使用Real-Q BKV定量试剂盒(Biosewoom,首尔,韩国)从98个血浆和57个尿液标本中提取了BK病毒的核酸(BKV DNA)。 PCR失败定义为BKV DNA阴性结果,根据制造商的说明,其内部对照的阈值循环超过36个。使用MDx系统从血浆样品中分离的核酸的PCR失败率与使用easyMAG系统处理的血浆样品的相似(分别为2.0%和3.1%)。使用MDx系统从尿液样本中分离的核酸的PCR失败率高于使用easyMAG系统处理的尿液样本(分别为33.3%和12.5%)。这些数据表明,通过easyMAG系统可以更有效地去除尿液样本中存在的PCR抑制剂。在扩增的样本中,从这两个系统获得的不一致结果表明,两个提取系统产生的BKV DNA的25个尿液样本的BKV DNA载量范围为2.3 log(10)拷贝/ mL至4.6 log(10)拷贝/ mL。 ,有15个样本(60.0%)通过easyMAG系统产生了更高的BKV DNA负载,表明easyMAG系统比MDx系统更有效地提取核酸。总之,当从尿液样品中提取BKV DNA时,easyMAG方法优于MDx方法。因此,基于磁珠的提取方法(如easyMAG系统)对于定量尿液中的病毒DNA是优选的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号