...
首页> 外文期刊>Journal of gastrointestinal surgery: official journal of the Society for Surgery of the Alimentary Tract >Functional lumen imaging probe to assess geometric changes in the esophagogastric junction following endolumenal fundoplication.
【24h】

Functional lumen imaging probe to assess geometric changes in the esophagogastric junction following endolumenal fundoplication.

机译:功能性腔成像探头,用于评估腔内胃底折叠术后食管胃交界处的几何变化。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: The functional lumen imaging probe (FLIP) uses impedance planimetry to measure the geometry of a distensible organ. The purpose of this study was to evaluate FLIP as a method to determine structural changes at the gastroesophageal junction (GEJ) following transoral incisionless fundoplication (TIF) and compare these findings with the accepted methods of esophageal testing. METHODS: Two different approaches (TIF1.0 and 2.0) using the EsophyX device were performed in six and five animals, respectively. Three dogs underwent a sham procedure. FLIP measurements were performed pre- and post-procedure and at 2-week follow-up. Upper endoscopy, manometry, and 48-h pH testing were also performed at each time point. FLIP was performed in ten patients before and 3 months after TIF. RESULTS: Following TIF procedures, there was a significant decrease in cross-sectional area (CSA) of GEJ compared to baseline; however, the CSA of both groups returned to baseline at 2-week follow-up. The FLIP results were supported with pH testing and correlated highly with both measures of GEJ structural integrity (LES and cardia circumference). Following TIF in humans, there was a decrease in GEJ distensibility compared to baseline that persisted to the 3-month evaluation. CONCLUSION: FLIP is able to measure and display changes in tissue distensibility at the GEJ, and results correlate with established methods of testing. FLIP may represent a single testing modality by which to diagnose GERD and evaluate the outcome after antireflux surgery.
机译:背景:功能管腔成像探头(FLIP)使用阻抗平面测量法来测量可扩张器官的几何形状。这项研究的目的是评估FLIP作为确定经口无切口胃底折叠术(TIF)后胃食管交界处(GEJ)结构变化的一种方法,并将这些发现与公认的食道检查方法进行比较。方法:分别对六只和五只动物进行了两种使用EsophyX装置的不同方法(TIF1.0和2.0)。三只狗接受了假手术。 FLIP测量在术前和术后以及2周的随访中进行。在每个时间点还进行了上镜,压力计和48小时pH测试。在TIF之前和之后3个月对10例患者进行了FLIP。结果:采用TIF程序后,与基线相比,GEJ的横截面积(CSA)显着降低;但是,两组的CSA在2周的随访中均恢复了基线。 FLIP结果得到pH测试的支持,并与GEJ结构完整性(LES和card门围)的两种测量高度相关。在人类进行TIF后,与持续3个月评估的基线相比,GEJ可扩展性降低了。结论:FLIP能够测量和显示GEJ组织可扩张性的变化,其结果与已建立的测试方法相关。 FLIP可能代表一种单一的测试方式,通过它可以诊断GERD并评估抗反流手术后的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号