Purpose: To compare the frequency of vena caval penetration by the struts of the Option and Günther Tulip cone filters on postplacement computed tomography (CT) imaging. Materials and Methods: All patients who had an Option or Günther Tulip inferior vena cava (IVC) filter placed between January 2010 and May 2012 were identified retrospectively from medical records. Of the 208 IVC filters placed, the positions of 58 devices (21 Option filters, 37 Günther Tulip filters [GTFs]) were documented on follow-up CT examinations obtained for reasons unrelated to filter placement. In cases when multiple CT studies were obtained after placement, each study was reviewed, for a total of 80 examinations. Images were assessed for evidence of caval wall penetration by filter components, noting the number of penetrating struts and any effect on pericaval tissues. Results: Penetration of at least one strut was observed in 17% of all filters imaged by CT between 1 and 447 days following placement. Although there was no significant difference in the overall prevalence of penetration when comparing the Option filter and GTF (Option, 10%; GTF, 22%), only GTFs showed time-dependent penetration, with penetration becoming more likely after prolonged indwelling times. No patient had damage to pericaval tissues or documented symptoms attributed to penetration. Conclusions: Although the Günther Tulip and Option filters exhibit caval penetration at CT imaging, only the GTF exhibits progressive penetration over time.
机译:目的:比较放置后计算机断层扫描(CT)成像中Option和GüntherTulip圆锥滤镜的支杆对腔静脉穿透的频率。材料和方法:从医疗记录中回顾性鉴定所有在2010年1月至2012年5月之间放置Option或GüntherTulip下腔静脉(IVC)过滤器的患者。在放置的208个IVC过滤器中,由于与过滤器放置无关的原因,在后续的CT检查中记录了58个设备(21个选件过滤器,37个GüntherTulip过滤器[GTF])的位置。如果在放置后获得了多个CT检查,则对每个检查进行复查,共进行80项检查。对图像进行评估,以了解是否有滤膜组件穿透了洞壁,并指出了穿透杆的数量以及对牙周组织的影响。结果:在放置后1到447天之间,CT成像的所有滤器中有17%观察到至少一个撑杆的穿透。尽管在比较Option过滤器和GTF时,总体渗透率没有显着差异(Option,10%; GTF,22%),但只有GTF显示出时间依赖性的渗透率,长时间的留置后渗透率更高。没有患者对牙周组织造成损害或因穿透而导致的症状记载。结论:尽管GüntherTulip和Option滤镜在CT成像中显示出腔穿透性,但只有GTF随时间显示出渐进式穿透性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号