To clarify the sealing characteristics of metal gasket seals, leakage rates of gas and the real contact area of the seal surfaces were measured under several closing loads. The static seal consisted of a ring-shaped copper gasket and the two steel flanges that held the gasket in place. Gasket widths in the radial direction were 2 mm, 3 mm, and 5 mm. The contact surfaces of the flanges were finished by lathe turning. To determine the leakage flow paths between the gasket and the flanges, the real contact situation between them was observed using a thin polymer film 1 μm in thickness. The results indicated the leakage flow paths on the gasket surface were the radial direction perpendicular to the lathe-turned groove and the circumferential direction along the groove. As the closing loads increased, the leakage flow in the radial direction ceased and only that in the circumferential direction remained. Therefore, the cross-section of the aperture for the leakage flow in the circumferential direction was evaluated from the measured real contact area, and the leakage rates were estimated by assumption of laminar flow. The results agreed well with the measured leakage rates.
机译:为了阐明金属垫片密封件的密封特性,在几个关闭载荷下测量了气体的泄漏率和密封表面的实际接触面积。静态密封包括一个环形铜垫圈和两个将垫圈固定在位的钢制法兰。垫片在径向上的宽度为2mm,3mm和5mm。法兰的接触面通过车床车削完成。为了确定垫圈和法兰之间的泄漏流动路径,使用厚度为1μm的聚合物薄膜观察了它们之间的实际接触情况。结果表明,垫圈表面上的泄漏流路是垂直于车削槽的径向,沿该槽的周向。随着闭合载荷的增加,沿径向的泄漏流停止,仅沿周向的泄漏流保留。因此,从所测量的实际接触面积评估了用于泄漏流的孔的横截面在周向上的方向,并且通过假设层流来估计泄漏率。结果与测得的泄漏率非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号