The precision of a Porcine reproductive and respiratory syndrome virus (PRRSV) oral fluid antibody enzyme-linked immunosorbent assay (ELISA) was evaluated by calculating reliability coefficients for assay repeatability (within laboratory) and assay reproducibility (between laboratories). Randomly ordered oral fluid samples of known (n=39) and unknown (n=224) PRRSV antibody status were tested in 12 diagnostic laboratories. Each laboratory tested the samples twice, first using an antibody ELISA kit and reagents provided to them (phase 1) and then using an ELISA kit and reagents configured in their respective laboratory (phase 2). Repeatability (within laboratory) reliability coefficients calculated using results from samples of known PRRSV antibody status ranged from 0.724 to 0.997 in phase 1 and from 0.953 to 0.998 in phase 2. Reproducibility (between laboratories) reliability coefficients were calculated for 3 conditions: case 1 - samples of unknown status (n=224); case 2 - samples of known status (n=39), and case 3 - all samples (n=263). Among the 3 cases, reliability coefficients ranged from 0.937 to 0.964 in phase 1 and from 0.922 to 0.935 in phase 2. For case 3, it was estimated that 96.67% of the total variation in phase 1 and 93.21% in phase 2 could be attributed to the oral fluid samples themselves. Overall, the PRRSV oral fluid antibody ELISA was highly repeatable and reproducible. The current study supports the routine use of this test in laboratories providing diagnostic service to pig producers.
机译:猪繁殖与呼吸综合症病毒(PRRSV)口服液抗体酶联免疫吸附测定(ELISA)的精度通过计算测定重复性(实验室内)和测定再现性(实验室之间)的可靠性系数进行评估。在12个诊断实验室中测试了已知(n = 39)和未知(n = 224)PRRSV抗体状态的随机排序的口腔液样本。每个实验室两次测试样品,首先使用抗体ELISA试剂盒和提供给他们的试剂(阶段1),然后使用ELISA试剂盒和在各自实验室中配置的试剂(阶段2)。使用已知PRRSV抗体状态的样品在第1阶段从0.724到0.997,在第2阶段从0.953到0.998范围内的结果计算得出的可重复性(实验室内)可靠性系数。针对以下3种条件计算了可重复性(实验室之间)的可靠性系数:案例1-状态未知的样本(n = 224);情况2-已知状态的样本(n = 39),情况3-所有样本(n = 263)。在这三种情况下,第一阶段的可靠性系数介于0.937至0.964之间,第二阶段的可靠性系数介于0.922至0.935之间。对于第三种情况,估计第一阶段的总变异为96.67%,第二阶段的总变异为93.21%。到口腔液样本本身。总体而言,PRRSV口服液抗体ELISA具有很高的重复性和可重复性。当前的研究支持在为生猪生产者提供诊断服务的实验室中常规使用该测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号