首页> 外文期刊>Journal of Veterinary Diagnostic Investigation >Activity, specificity, and titer of naturally occurring canine anti-DEA 7 antibodies
【24h】

Activity, specificity, and titer of naturally occurring canine anti-DEA 7 antibodies

机译:天然犬抗DEA 7抗体的活性,特异性和效价

获取原文
获取原文并翻译 | 示例
       

摘要

The reported prevalence of naturally occurring anti-dog erythrocyte antigen (DEA) 7 antibodies in DEA 7-negative dogs is as high as 50%. Characterization of these antibodies may better define their importance in canine transfusion medicine. We determined in vitro activity, specificity, and titer of anti-DEA 7 antibodies in DEA 7-negative dogs. Plasma samples from 317 DEA 7-negative dogs were cross-matched with DEA 7-positive red blood cells (RBCs) using gel column technology. Agglutination occurred with DEA 7-positive RBCs but not with DEA 7-negative RBCs in 73 samples (23%), which were hence classified as containing anti-DEA 7 antibodies. These samples were evaluated for hemolytic and agglutinating activity, strength of agglutination, and antibody specificity and titers. All samples showed agglutination but none showed hemolysis. Gel agglutination was graded as 1+ for 20 samples (27%), 2+ for 49 samples (67%), 3+ for 4 samples (6%); no samples were graded 4+. The agglutination titer was 1:2 for 51 samples (73%), 1:2 for 13 samples (19%), 1:4 for 4 samples (5%), and 1:8 for 2 samples (3%). Of 16 samples treated with 2-mercaptoethanol, 11 samples (69%) contained only IgM, 4 samples (25%) exhibited only IgG activity, and 1 sample (6%) had both IgG and IgM activity. Low titers of warm, weakly agglutinating, mostly naturally occurring IgM anti-DEA 7 antibodies were found in 23% of DEA 7-negative dogs. The presence of naturally occurring anti-DEA 7 antibodies suggests that cross-matching of canine blood recipients is advisable, even at first transfusion, to minimize delayed transfusion reactions.
机译:已报道在DEA 7阴性狗中天然存在的抗狗红细胞抗原(DEA)7抗体的患病率高达50%。这些抗体的表征可以更好地定义其在犬输血医学中的重要性。我们确定了DEA 7阴性狗的抗DEA 7抗体的体外活性,特异性和效价。使用凝胶柱技术,将来自317个DEA 7阴性狗的血浆样品与DEA 7阳性红细胞(RBC)交叉匹配。在73个样本(23%)中,DEA 7阳性RBC发生凝集,而DEA 7阴性RBC则不发生凝集,因此被归类为含有抗DEA 7抗体。对这些样品的溶血和凝集活性,凝集强度以及抗体特异性和效价进行评估。所有样品均显示凝集,但均未显示溶血。凝胶凝集分为20个样品(27%)为1 +,49个样品(67%)为2 +,4个样品为3+(6%)。没有样品被评为4+。 51个样品(73%)的凝集滴度<1:2、13个样品(19%)的凝集滴度<1:2、4个样品(5%)的1:4和2个样品(3%)的1:8。在用2-巯基乙醇处理的16个样品中,有11个样品(69%)仅包含IgM,4个样品(25%)仅显示IgG活性,而1个样品(6%)同时具有IgG和IgM活性。在23%的DEA 7阴性狗中发现了低滴度的温暖,弱凝集的,大多数为天然的IgM抗DEA 7抗体。天然存在的抗DEA 7抗体的存在表明,即使在首次输血时,也建议对犬血液受体进行交叉匹配,以最大程度地减少延迟的输血反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号