首页> 外文期刊>Journal of the Society for Gynecologic Investigation >The measurement of dendritic cells in umbilical cord blood: a novel technique using small volumes of whole blood.
【24h】

The measurement of dendritic cells in umbilical cord blood: a novel technique using small volumes of whole blood.

机译:脐带血中树突状细胞的测量:一种使用少量全血的新技术。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: To develop a technique that would permit the identification of dendritic cells (DC) in small volumes of preterm neonatal cord blood in order to investigate neonatal immune response in relation to infection and preterm labor. METHODS: We used three-color flow cytometry and a fixed quantity of fluorospheres to determine absolute cell numbers. Four red cell lysis techniques, sample dilution, time delay experiments, and a comparison with traditional Ficoll cell separation techniques were performed. Absolute numbers of DC recovered using each technique were calculated and compared. RESULTS: With increasing time delay, there was a statistically significant reduction in the numbers of leukocytes in adult blood. In contrast, there was a significant increase in leukocytes in umbilical cord blood. Sample dilution did not significantly affect the total number of leukocytes or DC. The use of the reagent Optilyse B (Immunotech, Oxford, UK) combined with an additional washing step produced the best discrimination of all populations based on light scatter properties. For the same blood sample, antibody labeling of whole blood resulted in a greater recovery of DC when compared to prior cell purification using a Ficoll density gradient. CONCLUSION: Using traditional Ficoll cell separation, cell manipulation requires large volumes of blood and leads to cell loss and alteration in phenotype. We have validated a novel method using small volumes of whole blood, diluted if necessary, and using red cell lysis to enable analysis of small volumes of preterm neonatal cord blood. This may permit further analysis of the contribution of the fetal immune response in the development of spontaneous preterm labor and preterm birth due to infection.
机译:目的:开发一种技术,以鉴定少量早产新生儿脐带血中的树突状细胞(DC),以研究与感染和早产有关的新生儿免疫反应。方法:我们使用三色流式细胞仪和固定数量的荧光球确定绝对细胞数。进行了四种红细胞裂解技术,样品稀释,延时实验以及与传统Ficoll细胞分离技术的比较。计算并比较了使用每种技术回收的DC的绝对数量。结果:随着时间延迟的增加,成人血液中白细胞的数量在统计学上显着减少。相反,脐带血中的白细胞显着增加。样品稀释不会显着影响白细胞或DC的总数。结合使用Optilyse B试剂(英国牛津的Immunotech)和额外的洗涤步骤,可以根据光散射特性对所有种群进行最佳区分。对于相同的血液样品,与先前使用Ficoll密度梯度进行的细胞纯化相比,全血的抗体标记导致DC的回收率更高。结论:使用传统的Ficoll细胞分离技术,细胞操作需要大量血液,并导致细胞损失和表型改变。我们已经验证了一种新方法,该方法使用少量全血,必要时进行稀释,并使用红细胞裂解法对少量早产新生儿脐带血进行分析。这可以允许进一步分析胎儿免疫应答在感染引起的自发性早产和早产中的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号