OBJECTIVES: In 3 of 5 patients with dystonia and bilaterally implanted deep brain stimulating electrodes, focal transcranial magnetic stimulation (TMS) of one motor cortex elicited bilateral hand motor responses. The aim of this study was to clarify the origin of these ipsilateral responses. METHODS: TMS and electrical stimulation of corticospinal fibres by the implanted electrodes were performed and the evoked hand motor potentials were analysed. RESULTS: In comparison with responses elicited by contralateral motor cortex stimulation, ipsilateral responses were smaller in amplitude (3.0+/-1.4 versus 5.8+/-1.5 mV), had shorter peak latencies (first negative peak: 20.9+/-0.8 versus 25.1+/-0.4 ms) and were followed by a shorter-lasting silent period (46+/-4 versus 195+/-35 ms). Ipsilateral responses following TMS had similar peak latencies to responses elicited subcortically by deep brain stimulation (DBS) (20.4+/-0.9 ms). CONCLUSIONS: Hand motor responses ipsilateral to TMS result from a subcortical activation of corticospinal fibres, via the implanted electrode in the other hemisphere, secondary to currents induced by TMS in subcutaneous wire loops that underlie the magnetic coil. Studies of TMS in patients with DBS have to take this potential source of confounding into account.
机译:目的:在5例肌张力障碍和双侧植入深部脑刺激电极的患者中,有3例中,一个运动皮层的局灶性经颅磁刺激(TMS)引起了双侧手部运动反应。这项研究的目的是澄清这些同侧反应的起源。方法:进行TMS和植入电极对皮质脊髓纤维的电刺激,并分析诱发的手运动电位。结果:与对侧运动皮层刺激引起的反应相比,同侧反应幅度较小(3.0 +/- 1.4对5.8 +/- 1.5 mV),峰潜伏期较短(第一个负峰:20.9 +/- 0.8对25.1) +/- 0.4毫秒),然后是较短的静音期(46 +/- 4对195 +/- 35毫秒)。 TMS后的同侧反应与深部脑刺激(DBS)皮层下诱发的反应具有相似的峰值潜伏期(20.4 +/- 0.9 ms)。结论:TMS同侧的手部运动反应是由于皮质半球皮层下的皮层下激活,通过另一半球中的植入电极,继而由TMS在电磁线圈下面的皮下线环中感应的电流产生的。 DBS患者中TMS的研究必须考虑到这种潜在的混淆因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号