This experimental work was carried out by turning of AISI 1040 medium carbon steel in which the effect of cryogenic cooling (LN_2) used as a cutting fluid is compared to that of dry machining with respect to tool wear i.e. crater and flank wear, surface roughness, cutting forces (feed and cutting forces) and cutting temperature. Experiments were performed using uncoated tungsten carbide insert tool having various feed rate and constant cutting speed. Compared to dry machining, in LN_2 machining, overall the tool wear were reduced to 55.45 and 65.53%, surface roughness was reduced to 125.90% and forces were reduced to 61.94 and 96.60%. The experimental results proved that the application of cryogenic coolant overall increases the machining performance as compared to dry machining.
机译:这项实验工作是通过对AISI 1040中碳钢进行车削而进行的,其中就刀具磨损(即月牙坑和后刀面磨损,表面粗糙度)而言,将用作切削液的低温冷却(LN_2)与干式切削的效果进行了比较。切削力(进给和切削力)和切削温度。使用具有不同进给速度和恒定切削速度的未涂层碳化钨刀片工具进行实验。与干式加工相比,在LN_2加工中,整体刀具磨损降低到55.45%和65.53%,表面粗糙度降低到125.90%,力降低到61.94和96.60%。实验结果证明,与干式加工相比,低温冷却剂的整体应用可提高加工性能。