...
首页> 外文期刊>Journal of the American Oil Chemists' Society >Simultaneous detection of tocopherols, carotenoids, and chlorophylls in vegetable oils by direct injection C-30 RP-HPLC with coulometric electrochemical array detection
【24h】

Simultaneous detection of tocopherols, carotenoids, and chlorophylls in vegetable oils by direct injection C-30 RP-HPLC with coulometric electrochemical array detection

机译:通过直接注入C-30 RP-HPLC和库仑电化学阵列检测同时检测植物油中的生育酚,类胡萝卜素和叶绿素

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Detection and quantification of tocopherols, carotenoids, and chlorophylls in vegetable oil have been used to aid their authentication. Their importance in influencing the oxidative stability of vegetable oils and their possible health benefits have been shown in numerous studies. Therefore, the need for a rapid and reliable analysis method has become increasingly important. This study demonstrates the application of C-30 RP-NPLC with electrochemical detection for the simultaneous analysis of tocopherols, carotenoids, and chlorophylls in vegetable oils. Aliquots of vegetable oils were dissolved in appropriate solvents and injected directly without saponification, thus preventing sample loss or component degradation. Effective separation of tocopherols, carotenoids, and chlorophylls was achieved. Detection was performed using a coulometric electrochemical array detector set between 200 and 620 mV. For a 25-muL injection, the respective detection limits for carotenoids, tocopherols, and chlorophylls were 1 fmol, 0.15 pmol, and 0.5 pmol, representing 1000-, 25-, and 5-fold enhancement over the UV-vis methodology. The detector response was linear between 0.01 and 2.00 mug/mL for all compounds studied. Within-day variations (CV) were between 2.0 and 6.3%, whereas between-day variations were between 2.7 and 7.4%. This method can be applied for rapid and sensitive analysis in the study of oil quality and adulteration.
机译:对植物油中的生育酚,类胡萝卜素和叶绿素的检测和定量已用于辅助其鉴定。在许多研究中已经表明了它们在影响植物油氧化稳定性方面的重要性及其对健康的潜在益处。因此,对快速可靠的分析方法的需求变得越来越重要。这项研究证明了具有电化学检测功能的C-30 RP-NPLC在同时分析植物油中的生育酚,类胡萝卜素和叶绿素方面的应用。将植物油等分试样溶解在适当的溶剂中,无需皂化即可直接进样,从而防止样品损失或组分降解。有效分离了生育酚,类胡萝卜素和叶绿素。使用设置在200至620 mV之间的电量电化学阵列检测器进行检测。对于25μL进样,类胡萝卜素,生育酚和叶绿素的检出限分别为1 fmol,0.15 pmol和0.5 pmol,比UV-vis方法提高了1000倍,25倍和5倍。对于所有研究的化合物,检测器响应在0.01和2.00杯子/ mL之间呈线性关系。日内变化(CV)在2.0和6.3%之间,而日间变化在2.7和7.4%之间。该方法可用于油质和掺假研究中的快速灵敏分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号