首页> 外文期刊>Journal of the American Veterinary Medical Association >Comparison of automated versus manual neutrophil counts for the detection of cellular abnormalities in dogs receiving chemotherapy: 50 cases (May to June 2008)
【24h】

Comparison of automated versus manual neutrophil counts for the detection of cellular abnormalities in dogs receiving chemotherapy: 50 cases (May to June 2008)

机译:比较自动和手动中性粒细胞计数在接受化疗的犬中检测细胞异常的情况:50例(2008年5月至2008年6月)

获取原文
获取原文并翻译 | 示例
           

摘要

Objective—To determine the frequency of clinically relevant abnormalities missed by failure to perform a blood smear evaluation in a specific subset of dogs receiving chemotherapy and to compare automated and manual neutrophil counts in the same population.Design—Retrospective case series.Animals—50 dogs receiving chemotherapy with a total nucleated cell count > 4,000 nucleated cells/(iL.Procedures—50 blood smears were evaluated for abnormalities that have strong potential to change the medical plan for a patient: presence of blast cells, band neutrophils, nucleated RBCs, toxic change, hemoparasites, schistocytes, and spherocytes. Automated and manual neutrophil counts were compared.Results—Blood smears from 10 (20%) patients had > 1 abnormalities. Blast cells were identified on 4 (8%) blood smears, increased nucleated RBCs were identified on 5 (10%), and very mild toxic change was identified on 2 (4%). Correlation coefficient of the neutrophil counts was 0.96. Analysis revealed a slight bias between the automated and manual neutrophil counts (mean ± SD difference, -0.43 X 103/uL ± 1.10 X 103/uL).Conclusions and Clinical Relevance—In this series of patients, neutrophil count correlation was very good. Clinically relevant abnormalities were found on 20% of the blood smears. An automated CBC appears to be accurate for neutrophil counts, but a microscopic examination of the corresponding blood smear is still recommended; further studies are needed to determine whether the detection or frequency of these abnormalities would differ dependent on chemotherapy protocol, neoplastic disease, and decisionthresholds used by the oncologist in the ordering of a CBC without a blood smear evaluation.
机译:目的—确定在同一群接受化学疗法的狗中没有进行血液涂片评估而漏诊的临床相关异常的频率,并比较同一人群中自动和手动中性粒细胞计数。设计—回顾性病例系列。动物—50只狗接受化学疗法的核细胞总数> 4,000个核细胞/(iL。程序—评估了50次血液涂片检查是否有可能改变患者医疗计划的异常:胚泡细胞,中性粒细胞带,有核红细胞,毒性结果:10例(20%)患者的血涂片异常> 1; 4例(8%)的血涂片上发现了母细胞; 4例(8%)的血涂片中发现了母细胞;核中性红细胞增多。在5(10%)处鉴定出中毒,在2(4%)处鉴定出非常轻微的毒性变化,中性粒细胞计数的相关系数为0.96。自动和手动中性粒细胞计数之间存在偏差(均值±SD差,-0.43 X 103 / uL±1.10 X 103 / uL)。结论和临床相关性—在这一系列患者中,中性粒细胞计数相关性非常好。在20%的血液涂片中发现了与临床相关的异常。自动化的CBC似乎对中性粒细胞计数是准确的,但仍建议对相应的血液涂片进行显微镜检查。需要进一步的研究来确定这些异常的检测或频率是否会根据化疗方案,肿瘤性疾病以及肿瘤学家在未进行血液涂片评估的情况下订购CBC所使用的决策阈值而有所不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号