首页> 外文期刊>Journal of the American Veterinary Medical Association >Identification and effects of common errors and artifacts on the perceived quality of radiographs
【24h】

Identification and effects of common errors and artifacts on the perceived quality of radiographs

机译:常见错误和伪影的识别以及对射线照片感知质量的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Objective - To identify common errors in film and digital radiographs provided by referring veterinarians and determine the effect of such errors on the perceived diagnostic quality of image sets.Design - Prospective study.Sample - 135 sets of radiographic images acquired by referring veterinarians for client owned small animals evaluated at a university hospital.Procedures-Sets of radiographs were prospectively collected and evaluated for proper performance of various radiographic technical variables including exposure, collimation, positioning, inclusion of all appropriate views, presence of artifacts, radiation safety, and labeling. Sets of radiographs were subjectively determined to be of diagnostic or nondiagnostic quality by 2 evaluators.Results - The variables exposure, correct positioning, absence of artifacts, and acquisition of all appropriate views were significantly associated with a determination of diagnostic quality for radiograph sets. Correct patient labeling, radiation safety, and x-ray beam centering and collimation were not associated with a determination of diagnostic quality for radiograph sets. The number of categories with errors was significantly associated with identification of radiograph sets as having diagnostic or nondiagnostic quality. Digital radiographs had a significantly lower number of image artifacts and significantly higher frequency of proper labeling versus film radiographs.Conclusions and Clinical Relevance - Results of this study suggested the technical variables proper exposure, proper positioning, absence of artifacts, and acquisition of all appropriate views were important for acquisition of sets of radiographs of highdiagnostic quality. Identification of these errors and adjustment of radiographic technique to eliminate such errors would aid veterinarians in obtaining radiographs of high diagnostic quality and may reduce misinterpretation.
机译:目的-识别由兽医提供的胶片和数字X射线照片中的常见错误,并确定此类错误对图像集的感知诊断质量的影响。设计-前瞻性研究。样本-135个由兽医推荐给客户的放射线图像集在一家大学医院对小型动物进行了评估。对程序集进行了前瞻性收集,并评估了各种射线照相技术变量(包括曝光,准直,定位,所有适当视图的纳入,伪影的存在,辐射安全性和标签)的适当性能。由两名评估员主观确定射线照相的集合是否具有诊断或非诊断质量。结果-变量暴露,正确定位,无伪影以及获得所有适当的视野与确定射线照相的诊断质量显着相关。正确的患者标签,放射线安全性以及X射线束居中和准直与X光片诊断质量的确定无关。带有错误的类别的数量与X射线照片集具有诊断或非诊断质量的识别显着相关。与胶片X射线照片相比,数字X射线照片的图像伪影数量明显减少,正确标记的频率明显更高。结论和临床意义-这项研究的结果表明,技术变量应包括适当的曝光,正确的位置,没有伪影以及获取所有合适的视野对于获取高诊断质量的X射线照片非常重要。识别这些错误并调整射线照相技术以消除此类错误将有助于兽医获得具有较高诊断质量的射线照片,并可减少误解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号