Industrial pallet rack systems are made up of three dimensional structural arrangement using cold-formed steel members. The rack columns (upright) have perforations at prescribed intervals to facilitate the assemblage of beams with end connectors. Tabs are used in connections due to which the joints are highly semi-rigid in nature. The diversity in the difference of stiffness and strength of connecting member makes, it is almost impossible to develop a generalised model for analytical prediction. This paper describes the beam-column connection tests carried out on a commercially available pallet rack system by adopting single cantilever test set-up. Five sets of combinations are identified based on variation in beam depth and number of tab connectors to study the connection flexibility. Three tests were performed for each set to bring in uniformity in the result taking the total number of tests to 15. Experiments conducted on steel end connectors and the results showed that a greater stiffness in the connection is achieved using connectors with more number of tabs and greater depth of the beam. A comparative study on arriving at the joint stiffness using the three different methods like the initial stiffness method, slope to half ultimate method and the equal area method is carried out. The calculation of joint stiffness by means of initial stiffness method is considered to overestimate the values when compared to the other two methods. Equal area method is concluded to be the most appropriate method in arriving at the joint stiffness of any pallet rack connection, due to its low variance arrived in the set population.
机译:工业托盘架系统由使用冷弯型钢构件的三维结构布​​置组成。机架柱(立柱)以规定的间隔开孔,以利于将梁与端部连接器组装在一起。接头用于连接中,因此接头本质上是高度半刚性的。连接构件的刚度和强度差异的多样性使得几乎不可能建立用于分析预测的通用模型。本文介绍了采用单悬臂测试装置在市售托盘架系统上进行的梁柱连接测试。根据光束深度和接片连接器数量的变化确定五组组合,以研究连接的灵活性。每组进行了三个测试,以使结果均匀,使测试总数达到15。在钢制端连接器上进行的实验表明,使用带有更多凸耳和多个连接器的连接器,可以实现更大的连接刚度。光束的深度更大。使用初始刚度法,斜率至半极限法和等面积法这三种不同的方法对接头刚度进行比较研究。与其他两种方法相比,通过初始刚度方法计算接头刚度被认为高估了该值。得出结论,等面积法是得出任何托盘机架连接的接头刚度的最合适方法,因为它在设定总体中的变化很小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号