Accurate image alignment is needed for computing three-dimensional reconstructions from transmission electron microscope tilt series. So far, the best results have been obtained by using colloidal gold beads as fiducial markers. If their use has not been possible for some reason, the only option has been the automatic cross-correlation-based registration methods. However, the latter methods are inaccurate and, as we will show, inappropriate for the whole problem. Conversely, we propose a novel method that uses the actual 3D motion model but works without any fiducial markers in the images. The method is based on matching and tracking some interest points of the intensity surface by first solving the underlying geometrical constraint of consecutive images in the tilt series. The results show that our method is near the gold marker alignment in the level of accuracy and hence opens the way for new opportunities in the analysis of electron tomography reconstructions, especially when markers cannot be used. (C) 2001 Elsevier Science (USA). [References: 29]
机译:从透射电子显微镜倾斜序列计算三维重建需要精确的图像对齐。到目前为止,通过使用胶体金珠作为基准标记获得了最佳结果。如果由于某种原因无法使用它们,则唯一的选择就是基于互相关的自动注册方法。但是,后一种方法是不准确的,并且正如我们将要说明的那样,它不适用于整个问题。相反,我们提出了一种使用实际3D运动模型但在图像中没有任何基准标记的情况下进行工作的新颖方法。该方法基于首先通过解决倾斜序列中连续图像的潜在几何约束来匹配和跟踪强度表面的一些兴趣点。结果表明,我们的方法在准确性水平上接近金标记对准,因此为电子断层扫描重建分析提供了新的机会,尤其是在无法使用标记时。 (C)2001 Elsevier Science(美国)。 [参考:29]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号