CCD cameras have numerous advantages over photographic film for detecting electrons; however the point spread function of these cameras has not been sufficient for single particle data collection to subnanometer resolution with 300 kV microscopes. We have adopted spectral signal to noise ratio (SNR) as a parameter for assessing detector quality for single particle imaging. The robustness of this parameter is confirmed under a variety of experimental conditions. Using this parameter, we demonstrate that the SNR of images of either amorphous carbon film or ice embedded virus particles collected on a new commercially available 4kx4k CCD camera are slightly better than photographic film at low spatial frequency (< 1/5 Nyquist frequency), and as good as photographic film out to half of the Nyquist frequency. In addition it is slightly easier to visualize ice embedded particles on this CCD camera than on photographic film. Based on this analysis it is realistic to collect images containing subnanometer resolution data (6-9 angstrom) using this CCD camera at an effective magnification of similar to 112000 x on a 300 kV electron microscope. (c) 2006 Elsevier Inc. All rights reserved.
机译:CCD相机在检测电子方面比照相胶片具有许多优势;但是,这些相机的点扩散功能不足以通过300 kV显微镜将单个粒子数据收集到亚纳米分辨率。我们已采用频谱信噪比(SNR)作为评估单粒子成像检测器质量的参数。该参数的鲁棒性在各种实验条件下得到了证实。使用此参数,我们证明在低空间频率(<1/5奈奎斯特频率)下,在新型的商用4kx4k CCD相机上收集的无定形碳膜或嵌入冰的病毒颗粒的图像的SNR略优于照相胶片,并且达到摄影胶片的奈奎斯特频率的一半。此外,在此CCD相机上比在胶卷上可视化冰中嵌入的颗粒稍微容易一些。基于此分析,使用此CCD相机在300 kV电子显微镜上以类似于112000 x的有效放大倍数收集包含亚纳米级分辨率数据(6-9埃)的图像是现实的。 (c)2006 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号