首页> 外文期刊>Biomedical sciences instrumentation >Ramped versus stepwise thermoelastic testing of latex and elastic tissues.
【24h】

Ramped versus stepwise thermoelastic testing of latex and elastic tissues.

机译:乳胶和弹性组织的斜热与逐步热弹性测试。

获取原文
获取原文并翻译 | 示例
           

摘要

Thermoelastic testing assesses the elastic mechanisms of polymers through measurement of the retractive force (f) of constrained samples with increasing temperature (T). f contains an entropic (fs) and an internal energy component (fe), where f= fs +fe. The elastic mechanism is normally described by the energetic contribution (fe/f). We have produced a novel thermoelastic testing device capable of performing "stepwise" or "ramped" temperature profiles and have shown excellent agreement between these two techniques for both latex and bovine elastin. Experiments on latex produced an fe/f= 0.18 +/- 0.05 (mean +/-SD, n=15, ramped protocol) that was independent of extension ratio and temperature. These results demonstrate the highly entropic elastic mechanism in this well-defined material. In agreement with previous studies, thef-T curves for elastin were non-linear, leveling off above approximately 60 degrees C. Previous studies quote fe/f for elastin within the 50-70 degrees C range where volume changes (via loss of water) of elastin are thought to be negligible. While we observed a mean fe/f for elastin of 0.18 +/- 0.04 at 70 degrees C (not significantly different from that of latex), the fe/f values for elastin were highly temperature-dependent over the entire experimental temperature range (20-90 degrees C). These observations may reflect a continuous water loss with increasing temperature in our samples. However, since thermoelastic analysis assumes that force depends only on temperature, other complicating factors must also be considered: e.g. thermal transitions such as microfibril denaturation. These complications call into question the physical meaning of fe/f reported for elastin at any temperature.
机译:热弹性测试通过测量受约束样品随温度(T)升高时的回缩力(f)来评估聚合物的弹性机理。 f包含一个熵(fs)和一个内部能量分量(fe),其中f = fs + fe。弹性机制通常由能量贡献(fe / f)描述。我们已经生产出了一种新型的热弹性测试设备,能够执行“逐步”或“倾斜”的温度曲线,并且在乳胶和牛弹性蛋白这两种技术之间均显示出极好的一致性。在乳胶上进行的实验产生的fe / f = 0.18 +/- 0.05(平均值+/- SD,n = 15,倾斜方案),与延伸率和温度无关。这些结果证明了这种定义明确的材料具有高度熵的弹性机制。与先前的研究一致,弹性蛋白的f-T曲线是非线性的,在大约60摄氏度以上趋于平稳。先前的研究引用弹性蛋白的fe / f在50-70摄氏度范围内(体积变化(通过失水))被认为是微不足道的。虽然我们在70摄氏度下观察到的弹性蛋白的平均fe / f为0.18 +/- 0.04(与乳胶的均值无显着差异),但在整个实验温度范围内,弹性蛋白的fe / f值与温度高度相关(20 -90摄氏度)。这些观察结果可能反映了随着样品温度的升高,水的持续流失。但是,由于热弹性分析假设力仅取决于温度,因此还必须考虑其他复杂因素:热转变,例如微原纤维变性。这些并发症使人们怀疑在任何温度下弹性蛋白的fe / f的物理意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号