首页> 外文期刊>Journal of liquid chromatography and related technologies >A Highly Sensitive Liquid Chromatography-Electrospray Ionization-Time of Flight/Mass Spectrometric Assay for the Quantitation of 4-Beta-Hydroxycholesterol and Its Application to in vivo Cytochrome P450 3a Induction by AGM-130
【24h】

A Highly Sensitive Liquid Chromatography-Electrospray Ionization-Time of Flight/Mass Spectrometric Assay for the Quantitation of 4-Beta-Hydroxycholesterol and Its Application to in vivo Cytochrome P450 3a Induction by AGM-130

机译:高灵敏度液相色谱-电喷雾飞行时间/质谱法测定4-β-羟基胆固醇及其在AGM-130诱导的体内细胞色素P450 3a诱导中的应用

获取原文
获取原文并翻译 | 示例

摘要

A liquid chromatography-electrospray ionization-time-of-flight/mass spectrometry (LC-ESI-TOF/MS) method was developed for the determination of 4-beta-hydroxycholesterol (4-HC) in rat plasma, to evaluate cytochrome P450 3A (CYP3A) induction liability of a novel cyclin dependent kinases (CDKs) inhibitor, AGM-130. The method consisted of sample preparation without derivatization reagents for high sensitivity such as picolinyl ester, which could be labor-intensive and time consuming. The 4% bovine serum albumin in phosphate-buffered saline as a surrogate matrix was used in the calibration curve and quality control samples for the determination of 4-HC. Stable isotope-labeled (SIL) 4-HC (d7-4-HC) was used as an internal standard. A quadratic regression (weighted 1/concentration), with an equation y=ax(2)+bx+c, was used to fit calibration curves over the concentration range of 3.01-2220ng/mL for 4-HC. For quality control samples at 15.0, 165, and 1820ng/mL from the qualification experiment, the within-run accuracy ranged from 95% to 105% with precision values 10% for 4-HC. This novel LC-ESI-TOF/MS method was successfully applied to evaluate the potential of CYP3A induction by 5-hydroxy-5-nitro-indirubin oxime (AGM-130) in rat.
机译:建立了液相色谱-电喷雾电离飞行时间/质谱(LC-ESI-TOF / MS)方法,用于测定大鼠血浆中的4-β-羟基胆固醇(4-HC),以评估细胞色素P450 3A (CYP3A)诱导的新型细胞周期蛋白依赖性激酶(CDKs)抑制剂AGM-130的责任。该方法由不使用衍生化试剂(例如吡啶啉酯)的样品制备(如高灵敏性的劳动密集型和耗时的高灵敏度)组成。在磷酸盐缓冲液中作为替代基质的4%牛血清白蛋白用于校正曲线和质量控制样品中,用于测定4-HC。稳定的同位素标记(SIL)4-HC(d7-4-HC)被用作内标。使用方程y = ax(2)+ bx + c的二次回归(加权1 /浓度)拟合4-HC在3.01-2220ng / mL浓度范围内的校准曲线。对于来自鉴定实验的15.0、165和1820ng / mL的质量控制样品,内部运行准确度范围为95%至105%,4-HC的精度值为10%。这种新颖的LC-ESI-TOF / MS方法已成功地用于评估大鼠体内5-羟基-5-硝基-靛玉红肟(AGM-130)诱导CYP3A的潜能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号