An improved method based on solid-phase extraction and high-performance liquid chromatography with fluorescence detection was developed for the determination of urinary 1-hydroxypyrene (1-OHP). The solid-phase extraction procedure, the excitation and emission wavelengths for 1-OHP, and the pH of the mobile phase were optimized. Excitation and emission wavelengths of 239 and 392nm, respectively, afforded much higher fluorescence response than the wavelengths reported in previous studies. Lowering the pH of the mobile phase significantly decreased the fluorescence response of 1-OHP but increased data reproducibility for urine samples. Under optimized conditions, the average relative standard deviation (n =5) of intra-day precision for 11 urine samples was 2.7% (range 0.8-4.0%). Because of the excellent data reproducibility, we expect the method to be useful for the determination of urinary 1-OHP, especially in biomonitoring projects involving high-volume screening.
机译:建立了一种基于固相萃取和高效液相色谱-荧光检测的改进方法,用于测定尿中的1-羟基py(1-OHP)。优化了固相萃取程序,1-OHP的激发和发射波长以及流动相的pH。激发和发射波长分别为239和392nm,比以前的研究报告的波长具有更高的荧光响应。降低流动相的pH值会显着降低1-OHP的荧光响应,但会增加尿液样品的数据重现性。在优化条件下,11个尿液样品的日内精确度的平均相对标准偏差(n = 5)为2.7%(范围为0.8-4.0%)。由于出色的数据可重复性,我们希望该方法可用于测定尿液中的1-OHP,尤其是在涉及大量筛选的生物监测项目中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号